Iseo X1R Smart Installation Manual Download Page 1

X

1R 

Smart

INSTALLATION GUIDE

    WARNINGS

ELECTRONIC SUPPORT SERVICE
iseozero1

.com

®

i s e o

. c o m

Iseo Serrature s.p.a 
Via San Girolamo 13 
25055 Pisogne (BS) 
ITALY
Tel. +39 0364 8821 
[email protected]

Download

Download

User Manual

Iseo Argo App

app.iseo.com

When you switch on X1R Smart for the first time

, the lock automatically updates, if necessary, connected devices: external and 

internal control modules and the Bluetooth radio module. This operation can take up to 50 seconds and it is indicated by the orange 
led on the external module continuously flashing. 

Do not switch off X1R Smart during this operation

 and do not press any button 

or disconnect any cable, in order to avoid device malfunctions.

Read this manual prior to use the device in order to ensure a safe and proper use.

Preserve this manual as future reference.

The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.

The instructions should be carefully followed during installation. These instructions and any maintenance instructions should be 

passed on by the installer to the user.

The product can be destined only for the use for which it was expressly made and, therefore, as an armored door lock for civil and industrial 

locations. Any other use is to be considered improper and dangerous.

Do not work on the door with the lock installed in order to prevent wood or metal residue getting into the lock.

Distance between striking plate and latch tip, completely in (from both motor or key), must be between 2 and 3mm.

Handle must not have any friction during the return phase.

Connecting rods must have a play of at least 1 millimeters so that the deadbolt does not remain subjected to traction in the rest 

position. This would compromise infact the latch to be correctly relased when recalled by key.

Connect the “remote opening command” input to 8÷30Vdc/ac power supply source (opto-insulated input).

To use the “door status” internal relay (30Vdc/Vac - 1A MAX), an external power supply source is mandatory. Fit therefore a cable gland to 

allow the cable to pass through the hinge side of the door

Electrical connections must be done according to the manufacturer’s istructions and in compliance with the current regulations.

When using a feeder as a direct power supply source (8÷30Vdc/ 30W MAX), fit a cable gland to allow the cable to pass through the hinge 

side of the door.

Single Action

 version allow to withdraws bolts and latch by handle at the same time. 

Standard

 version allow to withdraws only the latch by 

handle.

 

ISEO Serrature S.p.A.

 

Via S. Girolamo, 13 

25055 - Pisogne – BS Italy 

 

 

 

 

 

0497/CPR/ 5706

 

17 

EN14846:2008

 

|3|X|9|E|0| P|7|1|3|  

 

 

0497/CPR/5705

 

17 

EN179:2008

 

|3|7|7|B|1|4|5|2|A|B|

 

DoP & Declaration of conformity available on the web site http://www.iseoserrature.it

x1R 696

x1R 699 SA

x1R 699 SA

Summary of Contents for X1R Smart

Page 1: ...ous Do not work on the door with the lock installed in order to prevent wood or metal residue getting into the lock Distance between striking plate and latch tip completely in from both motor or key must be between 2 and 3mm Handle must not have any friction during the return phase Connecting rods must have a play of at least 1 millimeters so that the deadbolt does not remain subjected to traction...

Page 2: ...42 max 38 max 0min 33max 15 3 n 4 x 6 37 37 37 30 262 40 14 2 39 2 28 28 28 28 410 35 164 65 n 3 x M5 L 3 8 12 13 21 31 33 262 108 n 2 x M6 To find all available versions and related codes check the IseoZero1 catalogue Add the plug indicated in the picture below only for Single Action version 2 VERSIONS ...

Page 3: ...2 Only if latch version 13mm Max latch projection adjustment 6mm LATCH ADJUSTMENT 4 DOOR CONTACTS REVERSIBILITY AND ADJUSTMENT It is forbidden to lubricate the door contacts It is possible to use ethyl alcohol to clean the door contacts 1 2 ...

Page 4: ...oes not remain engaged which will cause the motor to rotate in neutral 1 2 6 DOOR CLOSED CONTACTS FIXING 21 5 43 54 3 5 mm TOP BOTTOM black red In the case of power supply via door contacts use an external power supply 8 30Vdc 30W Low voltage contacts Do not touch with your fingers Do not connect to power supply that exceed the indicated ones Respect power polarity It is forbidden to lubricate the...

Page 5: ...l panel 50 50 25 25 50 33 0 max 93 Make a 50 mm diam hole only in the external panel in order to install the external cylinder protection Make a 25x25 mm slot in the outside panel and plate to allow the external module cable to pass through Keyboard with RFID reader Only RFID reader ...

Page 6: ...7 1 INTERNAL SIDE DOOR ASSEMBLING Internal control module assembling on the internal panel 50 50 200 max 93 Internal control module is not necessary if Single Action version Opening and closing buttons ...

Page 7: ...rd version 3 Alkaline batteries 4 Power supply 8 30Vdc 30W 5 Cable gland 6 Bipolar cable connection for remote opening command 7 Bipolar connection cable kit 8 Multifunction connection cable 8 pins 9 BATTERY HOLDER HOUSING 84 38 110 min 250 Before powering the x1R Smart make sure the red and black wires are intact and the battery housing connector does not come into contact with the door frame in ...

Page 8: ...act Relay normally open contact Negative power supply Opening command 8 30Vdc ac Relay normally closed contact Not used Positive power supply 8 30Vdc 30W MAX Opening command 8 30Vdc ac brown 4 blue 8 alkaline Relay 30Vdc Vac 1A MAX Only to use X1R Smart without external reader and keyboard functioning as an actuator place the jumper available in the package in the PINs 1 and 2 of connector JP1 Tak...

Reviews: