5
Fault list
Repairs to the product's electrical components should only be performed by a qualified
electrician. Otherwise there is a risk of electric current causing fatal injuries.
Problem/Fault
Possible cause(s)
Remedy
Increased noise while
running
Dirt
Clean the linear unit
Stiffness
Dirt
Warping
Clean the linear unit
Alignment , adjustment
Increased wear
(Friction)
Overload
Lack of lubricating film
Reduce load
Shorten servicing interval
Increased play on
shaft slots/trolley
Wear
Overload
Reduce the prestressing
Reduce load
Shorten servicing interval
Reset the prestressing
Important: A hostile electromagnetic environment can cause faults.
Do not attempt to manipulate the controller or output stage of the linear unit.