19
isel
-flat bed installation GFV
S
S
S
S
S
S
S
S
You will find two black plastic stoppers on the side of the
Z-axis. Beneath these, the lubricating nipples are to be seen
when the slide is located at the upper or lower end limiting
switch position.
Remove the stoppers, push or move the slide to the end
limiting switch position* and lubricate through the now visible
lubricating nipples (S) (two above, two below).
S
in all drawings, this shows a lubricating nipple or the
access to the lubricating points.
The Y-axis is built up as the Z-axis.
Grease on the right and on the left
side through the lubricating
nipples.
If you loosen the incoming feed
tubes to the right in the cable
duct, in order to obtain better
access to the lubricating nipple,
you must also tighten them up
again afterwards.
With the X-axis, the linear driving
mechanism is located on the work
top.
Remove the plastic stoppers on
the inside and lubricate in the
same way as the other axes
(once each in the front and at the
back).
The angular gears below the work top are maintenance-free.
* If the machine is off, you can move the slides of the Y- and Z-axis manually to
the limit switches.