Command
Description
:READ
:FIRM
ware
:NAME?
Query the device firmware name.
Example: :READ:FIRMWARE:NAME? H201C0
→
:REL
ease
?
Query the device firmware version.
Example: :READ:FIRMWARE:RELEASE? 2.35
→
Notes:
1) – only for HPS ≥ 1.5 kW and HPS compact (350 W)
2) – only for HPS ≥ 1.5 kW
3) – all “USER” command only for HPS compact 350 W
4) – only for HPS 300/800 W
6.1.1 ARC Management configuration for HPS ≥ 1.5 kW
The following example shows how to configure the ARC management to a full ARC recovery of 200 ms. For more information
about the ARC management, refer to the devices hardware manual.
The ARC management settings are permanently stored in the processors internal flash and are therefore restored after power-
on. Therefore these commands only need to be sent once.
: C O N F : A R C : CO N T
˽
1
A c t i v a t e th e AR C m a n ag e m e n t
: C O N F : A R C : N U M
˽
1 0
A l l o w up t o 1 0 A R C s . . .
: C O N F : A R C : T I M E
˽
1
. . . du r i n g o n e s ec o n d
: C O N F : A R C : W A I T
˽
1 0 0 E - 3
W a i t t i m e b e t we e n t wo AR C s i s 1 0 0 m s
: C O N F : A R C : R AM P
˽
1 E 5
V o l t a g e ra m p a f t e r A R C i s 1 0 0 k V / s ( 1 0 0 0 0 % o f V
n o m
= 1 0 k V )
SCPI protocol common instruction set | Last changed on: 2020-10-07 |
www.iseg-hv.com
41/61