4.6 Replacing the battery fuse
The batteries inside the power supply are fused to prevent damage in case of failure as they can deliver very high currents. The fuse
needs to be inserted by the user, if you operate the crate for the first time.
Also it is mandatory to remove the fuse for transportation, to
comply with the safety regulations!
The fuse is accessible on the back of the power supply unit, follow the steps described in 4.1 for
detaching the case lid. Insert the fuse firmly in the slot next to the mains connector labeled „ACCU-Fuse“.
Figure 7: replace battery fuse
Fuse specification
Automotive blade fuse, size MAXI, rated 32VDC, 50A, time delay
5 Compatibility lists
MMS CRATE CONTROLLERS
NOTES
CC24 – Master controller
with Linux and iCS2, Ethernet and WiFi, 2 Slave CAN Lines
All series
CC23 – Slave controller
Slave controller for use with CC24 system
All series
Wiener MPOD Controller
MPOD Controller built since 2016
MMS HIGH VOLTAGE MODULES
NOTES
EHS series
Standard and High precision, CG / CFG / FG Floating, unipolar
All series
please refer controller manual
for firmware requirments
EDS series
Cost effective distributor module. CFG, unipolar
EBS series
Bipolar 4 quadrant module, CFG, bipolar,
ESS series
High power 2 quadrant module, sink and source, FG, unipolar
ECH5xA – 10 Slot MMS Crate | Last modified on: 07.10.2019| www.iseg-hv.com