
6700SR Refrigerated Sampler
25
Selecting an Extended Program
To select an extended program, follow the steps in Example 4.
Module Programming
The module programming screens contain a branch of setup screens
that let you specify the units of measure and data storage interval.
Some module setup screens are available to you even when no mod-
ule or rain gauge is attached to the sampler. When you attach a 700
Series Module to the sampler, the sampler adds an additional set of
screens needed to program the module. Because each model is differ-
ent, the sampler adds a different set of screens. The module’s screens
work in the same way as the sampler’s screens. Menu charts for the
modules appear in the manuals shipped with each module.
1
6700 SAMPLER,
EXTENDED PROGRAMMING
For HELP at any
screen, press ? key.
Press the
On/Off
key to turn the sampler on. Press
↵
(Enter) to clear the
start-up message.
If the words “STANDARD PROGRAMMING” appear on the second line of
the start-up message, the sampler is using the standard programming
screens. To see the extended screens, type
6700.2
at the main menu shown
in step 2.
2
RUN “EXTENDED 1”
PROGRAM
VIEW REPORT
OTHER FUNCTIONS
Select PROGRAM from the main menu.
3
PROGRAM NAME:
"EXTENDED 1"
SITE DESCRIPTION:
"______"
Select PROGRAM NAME: "EXTENDED 1" from the quick view menu.
4
SELECT NEW PROGRAM
CHANGE PROGRAM NAME
Select SELECT NEW PROGRAM to change the program.
You can go through QUICK VIEW screens quickly by pressing
↵
(Enter) at
each screen. You can also change settings in quick view screens; see
Changing Settings in a Quick View Screen on page 19.
5
“EXTENDED 1”
“EXTENDED 2”
“EXTENDED 3”
“EXTENDED 4”
Select the name of the extended program you want to use.
Each program’s name appears on the same line. If you inadvertently give
two programs identical names, you can still identify them by their location
on the screen.
•
•
•
6
PROGRAMMING COMPLETE
RUN THIS PROGRAM
NOW?
YES NO
To run the program immediately, select YES. To run the program later,
select NO.
7
RUN “EXTENDED 2”
PROGRAM
VIEW REPORT
OTHER FUNCTIONS
Example 4 Selecting a Stored Extended Program
Summary of Contents for 6700SR
Page 2: ......
Page 4: ......
Page 18: ...6700SR Refrigerated Sampler iv...
Page 148: ...6700SR Refrigerated Sampler 130 Appendix B Material Safety Data Sheets...
Page 149: ...6700SR Refrigerated Sampler 131...
Page 150: ...6700SR Refrigerated Sampler 132...
Page 151: ...6700SR Refrigerated Sampler 133...
Page 152: ...6700SR Refrigerated Sampler 134...
Page 153: ...6700SR Refrigerated Sampler 135...
Page 154: ...6700SR Refrigerated Sampler 136...
Page 155: ...6700SR Refrigerated Sampler 137...
Page 156: ...6700SR Refrigerated Sampler 138...
Page 157: ...6700SR Refrigerated Sampler 139...
Page 158: ...6700SR Refrigerated Sampler 140...
Page 159: ...6700SR Refrigerated Sampler 141...
Page 160: ...6700SR Refrigerated Sampler 142...
Page 161: ...6700SR Refrigerated Sampler 143...
Page 162: ...6700SR Refrigerated Sampler 144...
Page 163: ...6700SR Refrigerated Sampler 145...
Page 164: ...6700SR Refrigerated Sampler 146...
Page 165: ...6700SR Refrigerated Sampler 147...
Page 166: ...6700SR Refrigerated Sampler 148...
Page 167: ...6700SR Refrigerated Sampler 149...
Page 168: ...6700SR Refrigerated Sampler 150...
Page 174: ...6700SR Refrigerated Sampler 156 Appendix D Replacement Parts REFRIGERATOR ASSEMBLY FRONT BACK...
Page 175: ...6700SR Refrigerated Sampler 157 REFRIGERATOR ASSEMBLY...
Page 176: ...6700SR Refrigerated Sampler 158 MODEL 6700 CONTROLLER INSIDE...
Page 177: ...6700SR Refrigerated Sampler 159 MODEL 6700 CONTROLLER INSIDE...
Page 178: ...6700SR Refrigerated Sampler 160 MODEL 6700 CONTROLLER OUTSIDE...
Page 179: ...6700SR Refrigerated Sampler 161 MODEL 6700 CONTROLLER OUTSIDE...
Page 180: ...6700SR Refrigerated Sampler 162 MODEL 6700 PUMP GEAR CASE ASSEMBLY...
Page 188: ...6700SR Refrigerated Sampler 170...
Page 190: ......