10
INDUSTRIAL SCIENTIFIC
Revision 5 (p/n: 17120932)
Event Log
The GasBadge Plus stores alarm events in non-volatile memory. The last 15 gas
alarm events are stored with continuous-loop logging.
The information stored for
each event is:
gas type
cumulative alarm time prior to alarm event
peak exposure level (ppm or %)
battery life remaining prior to alarm event
alarm duration in minutes/seconds
relative time that alarm occurred.
Battery Life Remaining
The Battery Life Remaining screen
presents the battery life remaining in
months. The battery indicator will be
active to present the battery screen as low,
medium, or full. The Month Icon will be
active to indicate that this is the number of
months. The instrument will continue to
indicate the sensor type on the auxiliary
display and the Checkmark Indicator if
appropriate.
Battery Life Remaining Screen – Months
After 30 seconds, this screen will timeout and return to the Gas Monitoring screen.
Pressing the Mode button at this screen will scroll to the Peak Gas Reading screen.
When there are 31 days or less of battery life remaining, the battery life will be
displayed in days, and the Days Icon will replace the Months Icon. When there are
24 hours or less of battery life remaining, the battery life will be displayed in hours,
and the Clock Icon will replace the Months or Days Icon.
Battery Life Remaining Screen – Days (Left) and Hours (Right)