pH min: <value> value without unit. Set minimal pH level that is acceptable. Value can be in the range of
6.5-7.1, standard value is 6.9.
pH max: <value> value without unit. Set maximal pH level that is acceptable. Value can be in the range of
7.0-7.5, standard value is 7.4.
pH desired: <value> value without unit. Set optimal pH level that is desired. Value can be in the range of
6.8-7.4, standard value is 7.2.
ORP min: <value> value in mV. Set minimal Redox (ORP) level that is acceptable. Value can be in the range
of 250-700mV, standard value is 650mV.
ORP max: <value> value in mV. Set maximal Redox (ORP) level that is acceptable. Value can be in the range
of 500-800mV, standard value is 750mV.
ORP desired: <value> value in mV. Set optimal Redox (ORP) level that is desired. Value can be in the range
of 400-750mV, standard value is 700mV.
CLF min: <value> value in mg/l. Set minimal free chlorine level that is acceptable. Value can be in the range
of 0.1-1.0 mg/l, standard value is 0.3mV.
CLF max: <value> value in mg/l. Set maximal free chlorine level that is acceptable. Value can be in the range
of 0.3-1.5 mg/l, standard value is 1.0mV
CLF desired: <value> value in mg/l. Set optimal free chlorine level that is desired. Value can be in the range
of 0.3-1.0mV, standard value is 0.5mV.
CL daily maximum: <value> value in ml. Set maximal daily chlorine dose.
After performing setup or any changes to this section, click „SAVE SETTINGS” to save configuration to
system
3.10.3
Values algaecide and flocculants
Setup of water treatment values for algaecide and flocculants has to be performed via LVLØ mobile
application in Service section; select Water treatment.
Algaecide initial: <value> value in ml. Setup initial dose value for algaecide based on vendor instructions.
Initial dose can be triggered only manually.
Algaecide daily: <value> value in ml. Setup daily dose value for algaecide based on vendor instructions.
Flocculants initial: <value> value in ml. Setup initial dose value for flocculants based on vendor instructions.
Initial dose can be triggered only manually.
Flocculants daily: <value> value in ml. Setup daily dose value for flocculants based on vendor instructions.
After performing setup or any changes to this section, click „SAVE SETTINGS” to save configuration to
system.
3.10.4
Dosing pumps assignment and flow rate
3.10.4.1
Overview
LVLØ is capable to operate up to four dosing pumps simultaneously. This ensures that all combinations of
dosing pumps needed for any water treatment technology can be achieved. Dosing pumps from any vendor
can be connected to the system. Dosing pump flow rate is configurable therefore it can dose more
precisely. Please note that filtration must be running to enable dosing of any chemicals.