In LVLØ the switch is used to give a signal to shut off the filtration pump and trigger an alert, in case of no
flow signal within 2 minutes after turning on the filtration pump. This will shut down all critical processes
like chemistry dosing, heating, backwash, etc., to avoid further damage on swimming pool equipment.
3.6.2
Electrical connection
Any flow switch with potential free digital output (On/Off) can be implemented within LVLØ hassle free
technology. Unused terminals of water level sensors can be used. Connection diagram for overflow edge
and skimmer pool is shown on pictures bellow:
3.6.3
Configuration
Flow switch setup has to be performed via LVLØ mobile application in Service section; select Filtration.
Flow switch: <not installed/optical/ultrasonic> Select proper flow switch configuration based on installation
type.
After performing setup or any changes to this section, click „SAVE SETTINGS” to save configuration to system.
3.7
AUX – Two auxiliary outputs
3.7.1
Overview
Countercurrent for everyday swimming, bubble feature for relaxing and revitalizing the muscles, waterfalls
for shoulder and neck massage; these and other unique water attractions improve general wellbeing,
reduce stress, turn a swimming pool into effective fitness feature and provide overall relax and fun.
LVLØ is ready to connect two independent high-current loads as it is equipped with two auxiliary outputs.
These outputs have motor circuit-breakers combined with contactor. This provides complete protection
for motors concentrated in a single product.
Optical: Overflow edge pool
Optical Water Level Sensor terminal
BLK – flow switch
BLU– flow switch
Ultrasonic: Skimmer pool
5V/3A terminal:
+5V – flow switch
Ultrasonic Level Sensor terminal:
0-10V – flow switch