INSTALLATION GUIDE
|
10
IM-Raptor-1.3.6-EN
4.3 Unpacking Device
♦
Inspect the package for damage before opening.
♦
Open the package and visually inspect all items for issues.
♦
Confirm that all items are available.
If there any missing or damaged items, contact iS5Com Support.
4.4
Prerequisites for Mounting Device on a Rack
Heat generated by the device is channeled outwards from the enclosure. For improved convectional airflow,
make sure that there is at least one rack-unit of space or 44 mm (1.75 in) of space around all sides of the
device or between the devices on the rack.
Forced airflow is not required. However, any increase in airflow will result in a reduction of ambient temperature
and improve the long term reliability of the equipment mounted in the rack space.
4.5
General Procedure for Installing and Starting Raptor
♦
Review the Compliance Specification (see section 10) for any regulatory requirements.
♦
Mount the device.
♦
Connect the failsafe alarm relay.
♦
Connect power to the device and ground the device.
♦
Connect the device to the network.
♦
Configure the device.
This equipment is intended only for use in a restricted access area.