iES24G Series User’s Manual
iS5 Communications Inc.
76
4.1.11
Warning
4.1.11.1
Fault Alarm
When any selected fault event had happened, the Fault LED in switch panel will light up and the electric
relay will signal at the same time.
Note: PWR 3 check box in the image above is not used.
The following table describes the labels in this screen.
Label
Description
Power Failure
Mark the box of PWR 1 and/or PWR 2 to monitor.
Port Link Down/Broken
Mark the box of port 1 to port 8 to monitor.
Apply
Click “Apply” to set the configurations.
4.1.11.2
System Warning
System Warning – SYSLOG Setting
The SYSLOG is a protocol to transmit event notification messages across networks. Please refer to RFC 3164
- The BSD SYSLOG Protocol.
The following table describes the labels in this screen.
Label
Description
IP Address
The remote SYSLOG Server IP address.
Apply
Click “Apply” to set the configurations.
Reset
Click “Reset” to return the last saved IP address.