Ti

160 Thermo Kwik 

INSTRUCTION MANUAL 

 

 
 
 
 
 
 
 
 

 

© 2012 

IR

tek International 

Specifications subject to change without prior notice. 

Summary of Contents for Ti160 ThermoKwik

Page 1: ...Ti160 Thermo Kwik INSTRUCTION MANUAL 2012 IRtek International Specifications subject to change without prior notice...

Page 2: ...pt for use for future transportation Do not drop shake or impact the thermal imager excessively in use or during transportation CAUTION Store the unit in its original case in a cool dry well ventilate...

Page 3: ...emperature Measurement 14 3 3 3 Freeze and Save Image 16 3 3 4 Viewing Stored Images 16 3 3 5 Export Saved Images 16 4 OPERATION GUIDE 17 4 1 Graphic Interface Description 17 4 1 1 Screen Graphic Inte...

Page 4: ...4 4 5 5 Delete 31 4 5 6 Format 32 5 TECHNICAL SPECIFICATIONS 32 TROUBLESHOOTING 34 APPENDIX A 35 Common Material Emissivity 35 APPENDIX B 36 Factory Default Parameter Setting Table 36...

Page 5: ...nsation 2X digital zoom Freeze screen for viewing current image Video output NTSC or PAL Area measurements Lines measurements Image storage via TF card CMOS visible image and storage Audio recording I...

Page 6: ...y Others z Iron and steel industry Inspect steel refining and rolling processes diagnose hot blast stove defects detect the embryo temperature of armor plate etc z Fire fighting Forest fire prevention...

Page 7: ...eporter software CD z TF card z TF card reader z USB cable 1 2 Optional Accessories z External 0 5x wide angle lens z External 2x telescopic lens z Eye patch z Power adapter with power cable z Euro st...

Page 8: ...t Auto key Marked A The A or attribute button performs 2 functions a The first function is modification of selected parameters It is obtained by a quick press and release less than 2 seconds with this...

Page 9: ...right arrow will reduce or increase the Span and pressing the up or down arrow will reduce or increase the Level If the unit is in Automatic mode modifying any of these parameters will select Manual m...

Page 10: ...key to pop up the attribute box Press four navigation keys to move the spot location In line temperature measurement editing mode activated immediately after adding a line or by selecting via the A k...

Page 11: ...pressing to initiate a Save cycle IR CCD Pulling and releasing trigger toggles between the IR image and the CCD image 7 Microphone Used for recording a voice message with the Saved image See Section 4...

Page 12: ...ower source should be 12VDC Center pin is positive terminal 3 BASIC OPERATION 3 1 Battery Installation and Replacement 3 1 1 Inserting or Removing Battery Battery compartment is located inside the han...

Page 13: ...torage so they should be fully charged before storage Self discharge may affect long term battery performance Furthermore it is recommended that the battery should be charged in a set time as below Am...

Page 14: ...ct the proper measurement parameter Aim the cursor indicator onto the target object on the screen The temperature will be displayed in the upper right corner of the screen For highest accuracy measure...

Page 15: ...Yes the displayed values of other measurements will be their delta from this measurement Line settings only include the emissivity Area settings can modify the emissivity area measurement type and ar...

Page 16: ...Menu key to activate the main menu Choose File Open to open the image z When image is opened choose Left or Right keys to select the previous or next images respectively z If the instrument is in IR m...

Page 17: ...atus 3 Spot temperature measurement White crosshair 4 Selected spot temperature Yellow crosshair 5 Emissivity Indicates Imagers emissivity setting 6 Minimum temperature Indicates minimum value of the...

Page 18: ...2 when digital zoom is activated NOTE Not all models have all functions so the working status screen may not show all features 4 1 2 Main Menu 1 Main menu Displays four options Measurement auto manual...

Page 19: ...enu Select Measurement and press Confirm key It will display the Measurement dialog box Use the Left and Right arrows to scroll through the available measurement options Highlight the option you wish...

Page 20: ...user Designated by 1 2 and 3 NOTE To delete a single object press A key to select the object and then press C key to delete 4 3 Auto Manually By adjusting the temperature and color corresponding rela...

Page 21: ...eSet and press Confirm key to pop up the Measuring Setup dialog box User can view or set temperature range lens type temperature unit ambient temperature reference type and reference temperature Press...

Page 22: ...etup Adjustment and press Confirm key to pop up the Adjustment dialog box User may set emissivity temperature correct and ambient temperature Press Up and Down keys to choose different items Left and...

Page 23: ...set to None only the audible alarm will sound When using alarms with Area measurements the selected measurement mode Min Max or Average will have to meet or exceed the set temperature in order to tri...

Page 24: ...up Allows the user to set the system date and time After setting the camera will save the current setting Press Menu key to activate the main menu Select Setup Date Time and press Confirm key to open...

Page 25: ...ibration Select Auto Calibration and press right arrow key Auto Calib mode dialogue box will pop up User can select from 3 modes long short or customize Customize can guide user to set the time interv...

Page 26: ...reen If set to None the function is disabled z AutoOffTime Allows user to select None 2 5 10 or 15 minutes If no button depressions are made during the set time the camera will turn off the main power...

Page 27: ...firm key to reset the factory default Press C key to cancel the reset operation Appendix B indicates the detailed factory default parameter table NOTE Default Reset function will delete all parameters...

Page 28: ...name created by Imager 2 Current displayed image file number 3 Total number of images currently stored 4 5 2 Save It is used for saving the image performs the same functionality as the Save key Press...

Page 29: ...menu allows enable disable of the CCD Camera and voice recording Press Confirm key to activate the main menu Select File Save Setting press Confirm key to display the Save Setting dialog box Press Up...

Page 30: ...rt the voice record cycle after confirmation of the save image No recording will occur with Voice Save set to Off Voice save setting is ignored with the Auto Save function NOTE To add voice comment to...

Page 31: ...interval 4 5 5 Delete Used for deleting the image When camera is in image replay mode press Menu key to activate the main menu select File Delete press Confirm key to pop out the below prompt box Pre...

Page 32: ...covered after formatting If formatting via PC please use FAT16 format 5 TECHNICAL SPECIFICATIONS Items Technical Specification Detector characteristics Detector type Un cooled FPA micro bolometer Arra...

Page 33: ...torage Storage card 2G SD card max 16G Storage mode Manual Auto single file saving IR and Visual image link saving File format Thermal JPEG with original thermal measurement data included Visual JPEG...

Page 34: ...5 seconds and reboot The camera powers off automatically z Battery is out of power Change battery z AutoOffTime option is enabled Set as None Battery depletion is too fast z Environmental temperature...

Page 35: ...21 Wrought iron Quarry faced 25 0 94 Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless steel Oxidized 60 0 85 Steel Oxidized 200 0 79 Common brick Surface 20 0 93 Concrete Surface 20 0 92 Glass Poli...

Page 36: ...rature correction table Parameter Value Emissivity 0 96 TCorrect 0 C TAmbient Temp Off Table 3 Analysis setting table Parameter Value Temp Alarm Off Alarming Temp 50 0 C Alarming Color None Isotherm C...

Page 37: ...IrReporter INSTRUCTION MANUAL 2012 IRtek International Specifications subject to change without prior notice...

Page 38: ...tes 12 3 6 Export the report as WORD file 12 3 7 Print setup 12 3 8 Print preview 13 3 9 Print report 14 3 10 Batch process 14 3 11 Exit 16 4 USE REPORT 17 4 1 System interface 17 4 2 Composing of rep...

Page 39: ...IRtek IrReporter Software Manual ii 4 8 Profile tool 31 4 9 Use histogram analytic tool 33 4 10 General operations of object 34 4 11 Page operations 35 5 USE USB 36...

Page 40: ...emory capacity hard disc space and also the high processing capability and high screen resolution z Recommend hardware configuration PENTIUM 1 4GHz CPU or higher 256 Mbytes or higher system memories 2...

Page 41: ...re the system will ask to enter the user name company name and the serial number Figure 1 2 3 Enter customer information Note All those three items must be entered or the next button will not be activ...

Page 42: ...n path is selected press Next button and it will pop up the below interface It allows you to double check the previous installation selection Figure 1 2 5 Start copying files interface Step 5 Press Ne...

Page 43: ...installation is finished it will pop up the below interface Press Finish button to complete the installation After that you can use the infrared reporter software Figure 1 2 7 Installation is finished...

Page 44: ...e Manual Figure 1 3 1 Shortcut of infrared reporter Double click on the icon and then the infrared reporter software will be started You can also go to Start menu to run the Infrared Reporter software...

Page 45: ...explained in this manual 2 1 The main interface of IrReporter Figure 2 1 1 Main interface of IrReporter When IrReporter software has been started the file window will also be opened up The window siz...

Page 46: ...IRtek IrReporter Software Manual 2 2 Menu bar 2 2 1 File menu 2 2 2 Edit menu...

Page 47: ...IRtek IrReporter Software Manual 8 2 2 3 View menu 2 2 4 Drawing menu 2 2 5 Windows menu...

Page 48: ...IRtek IrReporter Software Manual 2 2 6 Help menu 2 3 Toolbar 2 3 1 Standard Toolbar 2 3 2 Drawing toolbar 2 3 3 Format toolbar 2 3 4 Measure toolbar 2 3 5 Page control toolbar 2 3 6 Adjust toolbar...

Page 49: ...hoose to create a plain report or use the prior made template to create a report 3 2 Open up saved reports If the amendments or verifications need to be done on saved reports please press icon on tool...

Page 50: ...menu the standard file saving dialog box will pop up By changing the file path or so to choose the needed saving path and input the file name press the save button to save The extension of the report...

Page 51: ...the saved file name the system will remind you The extension of the report file is rpt and rpm 3 6 Export the report as WORD file The system can convert the current operating pager into WORD file Sel...

Page 52: ...al Figure 3 7 1 Print Setup 3 8 Print preview User can view the created report in two ways 1 Click on the button on the toolbar 2 By select file print preview in submenu the preview interface is as be...

Page 53: ...tly the standard print dialog box will popup show as below Figure 3 9 1 Print report 3 10 Batch process The system can process a serial of images if the requirements are similar and based on a templat...

Page 54: ...e a batch setting dialog box will appear as below Figure 3 10 2 Batch setting A saving path or pictures that need to process can be selected If Picture is selected click on Next the picture setting di...

Page 55: ...n set If the report has been selected click on next the select template path dialog box will appear as below Figure 3 10 4 Select template path After the template has been selected click on OK the cor...

Page 56: ...ftware is 1024x768 pixels Figure 4 1 1 Main interface 4 2 Composing of report contents The report mainly compose of infrared thermal images and analysis CCD pictures formatted text result lists tables...

Page 57: ...ome a cross hair click the left mouse button and held the button draw the mouse a changing size rectangular will show on the page release the mouse a new IR object will be created on the page Such as...

Page 58: ...an analysis submenu will pop up as below Figure 4 3 2 1 By menu Click on Open in the submenu the window with the DLI extension infrared thermal image files will popup for preview show as below change...

Page 59: ...nalysis can be done after importing the infrared thermal image The analysis toolbar mainly include 1 Spots analysis additional spots after clicking on this button move the mouse to the corresponding t...

Page 60: ...uitable position and a new analytic rectangular will be created upon the diagonal of the start position and release position There is no amount limit on analytic rectangular the system will title the...

Page 61: ...ve line move the line entirely Modify line set another spot as centre of the circle to rotate or flex Move rectangular move rectangular entirely or change size Modify rectangular change rectangular si...

Page 62: ...to delete Clear all analyses move mouse to corresponding infrared image click on mouse right button to pop up infrared image analysis submenu select the remove analysis this will clear all the analysi...

Page 63: ...IRtek IrReporter Software Manual 24 4 3 4 1 Image display setup Figure 4 3 4 1 1 Image display setup There are two selections for image display as above 4 3 4 2 Thermal images parameters setup...

Page 64: ...ow User can change the setup of each parameter to select different display effect of analytic image which include color display maximum minimum and average date and also adjust the emissivity or dista...

Page 65: ...ck If the selected image object has a voice involved in the voice button in analysis toolbar will be in implement state press this button to playback the voice 4 4 Use CCD image object CCD images are...

Page 66: ...ed image the item in the submenu will not be active 4 5 Use formatted text object Formatted text object is a powerful text edition function it support multi formatted text in same object also support...

Page 67: ...need to be changed use button in main interface toolbar Select text object if text object background color need to be changed use button in main interface toolbar select the background color needed T...

Page 68: ...p will not take effect The result after selection shows as below Figure 4 6 1 Example of use properties 4 7 Use table tool Click on table tool button in object toolbar and make it in active move the m...

Page 69: ...cting Properties a configuration dialog box will pop up Figure 4 7 1 Use table tool In configuration dialog box the cell type and background color can be affirmed show as below Figure 4 7 1 Properties...

Page 70: ...on the changing box which indicate the position and size of the object will appear release the button a new linear analysis object will be created The linear analysis object has to link with the corre...

Page 71: ...sponding color Show as picture below select relative infrared object number and line number and press Ok to confirm User can choose several lines to analyze at one time Figure 4 8 2 Color selection of...

Page 72: ...ct Click on profile tool button in object toolbar and make it in active move the mouse to plain space on the page the mouse symbol become a cross hair press mouse left button and hold on the changing...

Page 73: ...select the object hold on mouse left button move the mouse system will show a rectangular to indicate the current position release mouse to confirm z Change object size After selecting the object use...

Page 74: ...elete It also can carry out by select Edit Delete in main interface 4 11 Page operations System can create new page optionally for multi page operation z Add page Click on Add page button in main inte...

Page 75: ...Last page Go to z Zoom on out page Using the page management toolbar in main interface to zoom in or out the page and adjust the vision Zoom in Zoom out Zoom fit 5 USE USB Connect on USB tune on the...

Page 76: ...OX 435 Joondalup W A 6919 Australia For more information call Phone 61 8 9305 2222 Fax 61 8 9305 0111 Email technical irtek temp com Website www irtek temp com 2012 IRtek International All rights rese...