The ON-PBD-815 is an optional device of IR-TEC’s OS-NET
wireless mesh network solution. This device is exclusively
designed to replace an existing wall switch/dimmer to
broadcast manual on/off/dim control commands to the
assigned group lighting, while also function as a network
node.
This sleek, low profile OS-NET device can be mounted into a
standard EURO wall box, operated by line voltage power, and
provide wireless control to the grouped lighting as required.
Each ON-PBD-815 can be assigned to control up to 4 lighting
groups via a 2-way handheld remote programmer.
A short press at upper/lower position of the button will
transmit a command to switch on/off the lighting of groups
assigned. Press and hold at upper/lower position of the
button will increase/decrease the output level of controlled
lighting respectively. A screwless snap-on wall plate is
supplied to create a modern, high-end appearance for all
spaces. By grouping the ON-PBD-815 with OS-NET sensors
and controllers, you can effortlessly achieve an
energy-efficient, code-compliant smart lighting control
through a state-of-the-art wireless sensor mesh network with
manual controls capability for presentation or special event.
Line Voltage OS-NET Button
INSTALLATION INSTRUCTIONS
OVERVIEW
P/N: Z50-00334-000
www.irtec.com
This product may be covered by one or more U.S. patents or patent applications.
Please visit www.irtec.com for more information.
ON-PBD-815
Lead the wires and strip the insulation with proper
length for connecting.
Connect the wires with the device according to the
wiring diagram shown above.
NOTE
: The ON-PBD-815 requires connecting neutral
wire for operation. To replace the existing wall switch
with no neutral wire, you may substitute the switched
line wire for the neutral of lighting in accordance with
electrical codes and regulations.
Carefully set the wires and mount the device into the
wall box with screws provided.
NOTE:
Do NOT mount the device upside down.
INSTALLATION
1.
2.
3.
INDOOR USE ONLY
Utilisation a L'interieur Uniquement
AVERTISSEMENT & PRUDENCE
WARNING & CAUTION
Turn power OFF at circuit breaker before installing .
Coupez l'alimentation au disjoncteur avant d'installer.
Unit: mm
30
86
86
72
60
72
54
DIMENSIONS
WIRING DIAGRAM
L
230VAC
N
PRELIMINARY
N L