User Instructions for Irrigatia IRR-SOL-C120 

 
Positioning 

 
Mount the controller close to the water source and  
low down so that the pump inlet is below the water 
line in the tank (Fig 1). The controller case is weather 
resistant but can be mounted inside if desired. The 
solar panel should be mounted, facing the midday sun 

within 5m of the controller’s location

. The panel can 

be plugged in to the socket on the base of the 
controller. The screw collar on the cable is for use 
where an extension cable is required if the panel must 

be more than 5m away. 
 

Water inlet strainer and level sensor 

 

 
Insert the inlet tube with the water strainer on the end so that the 
tube is vertical in the tank and the strainer is resting on the bottom 
(fig 2). The water level sensors should be attached to this so that one 
is 2 -3 cm above the inlet hole, one hanging well below it (fig 3). 
 
During operation, if one of the sensors is out of the water the pump will stop 
and the beeper will sound. If the beeper is a nuisance it can be silenced by 
unplugging it from the circuit board. 
 
 

 
 
 

Water outlet tube & filter 

 
to protect the drippers from sediment, there is a fine 
mesh filter. This can be fitted on either side of the 
pump, (fig 1) but a valve must be fitted between it and 
the tank to turn off the water flow while cleaning. 
(Valve 3 in fig 1) 
 
 
 
 

 
 

 

Figure 3 

 

 

Figure 2 

 

 

Figure 1 

 

 

Figure 4 

 