1.  

OVERVIEW

Z-5R NET 

controller is used to control access to residential and industrial areas, log access and 

other security events.

Z-5R NET

 is connected to network via RS-485 (2-wire connection). 

-  Contact key reader (iButton

 

probe);

-  Electromechanical lock/latch;

-  External buzzer, external LED (same as the ones present on controller's PCB);

Proximity card readers can be connected to the controller via iButton or Wiegand-26 protocols.

-  Contactless card reader working via iButton

 

(DS1990A emulation) or Wiegand-26 protocols;

The controller can operate in standalone mode or as networked device.

Z-5R NET

 can work with the following equipment:

-  Electromagnetic lock

-  Door release button (normally open);

-  Door sensor (normally open type).

page 1

Z-5R 

NET

www.ironlogic.

me

Figure 1:

 Device dimensions

47 mm

65

 

mm

20 mm

65

 

mm

2. 

 CONNECTING AND MOUNTING

USB

RS

-

485

converter

USB - 

RS-485

(Z397)

Z-5R Net

controller

+12 V 

power

Reader

MATRIX II

Reader

MATRIX II

Entrance

Exit

Door sensor 

Lock

Door 
button

Figure 2:

 Z-5R NET Connections Layout

Summary of Contents for Z-5R NET

Page 1: ...ted to the controller via iButton or Wiegand 26 protocols Contactless card reader working via iButton DS1990Aemulation or Wiegand 26 protocols The controller can operate in standalone mode or as networked device Z 5R NET can work with the following equipment Electromagnetic lock Door release button normally open Door sensor normally open type page 1 Z 5R NET www ironlogic me Figure 1 Device dimens...

Page 2: ... sensor 12 V power Battery holder TM button Note To get the reader working at specified distance please use a UTP cable such as CAT5e When connecting via iButton one wire is connected to GND another to DATA0 terminals When connecting via Wiegand 26 first twisted pair is attached to GND and DATA0 and second to GND and DATA1 Figure 4 Connecting readers GND TM EXIT LED LOCK 12V GND DOOR ZUMM DATA 0 1...

Page 3: ...r key long touch At the moment of contact the controller will issue a short signal confirming the master key identification and after 6 seconds a second signal indicating the controller transition to the mode of adding simple keys After that the master key should be removed To add new keys touch the contactor in a sequence with a pause between touches for less than 16 seconds For each contact with...

Page 4: ...ch and entering programming mode On the third touch the Controller emits three short beeps denoting third Master Key touch Within 6 s after that touch and hold the probe with the Master key long touch On the fourth touch the controller emits four short beeps and in 6 s a series of short beeps acknowledging that controller has erased its key memory entirely and left the programming mode Take away t...

Page 5: ...tivate Blocking mode and revert to normal operation touch the probe shortly with a Blocking key or a Master key waiting for a series of short beeps to acknowledge that Blocking mode is deactivated 8 Accept Mode 5m To deactivate Accept mode afterwards touch the reader with a Master key again a series of short beeps will acknowledge exit from this mode Note If the supply power fails whileAccept mode...

Page 6: ... so please power the Controller OFF install the jumper and power it back ON A signal acknowledges Add Normal Keys mode Both Normal and Blocking Keys can be now added without a Master Key Note This will erase the entire keys database along with the custom Opening Time setting The Opening Time gets reset to factory default 3 seconds jumper open by default electromagnetic lock normally open After 16 ...

Page 7: ...re set to 3 0 sec Event log memory 2048 Normal Keys for passing the door Controller network logical address is initially set to 1 Maximum cards keys number 2024 4 SPECIFICATIONS Weight 80 g Maximum Controllers on the network 255 If a door sensor is present additional events Door broken in and Door not closed become available To avoid real time clock failure in case of power failure install a 3V CR...

Page 8: ... as required free of charge in cases where the fault is caused by a Manufacturer s defect 10 IRONLOGIC CONTACTS Development and production 7 Bobruiskaya street Saint Petersburg 195009 Russian Federation Phone 78122411853 78125421185 www ironlogic ru Authorized representative in the European Union SIA IRONLOGIC E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlo...

Reviews: