background image

 

 

 

 

 

 

IRIS Touch 

  

Quick Installation & 

Maintenance Guide 

 
 

Version 1.0 

 

 

 

 

Summary of Contents for Touch 4 Series

Page 1: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0 ...

Page 2: ...Page 2 of 16 IRIS Touch Quick Installation Maintenance Guide Version 1 0 ...

Page 3: ...ting 7 6 1 Power 7 6 2 Connections 7 6 3 GSM SIM card IRIS Touch 400 440 8 6 4 Dial capture 8 6 5 PIN Inputs 9 6 6 Expansion board 9 6 7 Switch on and test 9 6 8 Configuration 10 6 9 Panel configuration 11 6 10 Testing 11 6 11 7 Maintenance 11 Confirm current status 12 7 1 Check software version Reflash 12 7 2 Communication paths checks 12 7 3 Test alarm panel alarms and communication to ARC 12 7 ...

Page 4: ...arkets The IRIS Touch offers a touch screen as standard for configuration local alerts and allows diagnostic and tests to be performed by the engineer Polling and alarm over communication paths of Ethernet and or GPRS 3G 4G and CDMA on request to the monitoring centre This manual describes a quick guide to the installation of products from the IRIS Touch For the full manual including multi lingual...

Page 5: ... Board Configuration IRIS Touch SYS LED LED Colour Indication Yellow flashing Not currently configured or indicating that there are some current faults outstanding Yellow constant Communicating and no current faults flickers on every poll DC Power Pin inputs RS485 Dial capture port RJ11 and screw terminals SIM Card Ethernet 2 SYS LED Ethernet 1 Expansion Board GSM Antenna RS232 TTL RS232 x 2 Relay...

Page 6: ...s Ethernet LAN network details are required in order to connect the IRIS Touch The following information should be obtained from the customer Fixed IP address or DHCP If using DHCP then the following information will not be required as will be assigned by the network IP address Gateway address Subnet mask address GPRS SIM Card and Access Point Name If the installation uses GPRS then a SIM card wil...

Page 7: ...ETH1 Connect the Ethernet cable from ETH1 to the local IP router switch or socket that has been allocated for the LAN WAN network IP connection GPRS enabled systems IRIS Touch 400 440 Cell Ant Fit the supplied T bar GSM antenna Note An external GSM antenna can be fitted if required Dial capture port optional and for more information see section below Expansion board for addition PIN inputs and PST...

Page 8: ... GPRS Network Scan detailed in the Section 6 9 Configuration you will be prompted when to insert the SIM card Dial capture 6 5 Dial capture enabled systems Connect either the dial port RJ45 or using the 2 dial screw terminals with the supplied RJ11 dialler cable to the alarm panel dialler telecoms line connection If the alarm panel has screw connections cut the connector off the cable and strip th...

Page 9: ...s It is also possible to link the contacts to the IRIS dialler via sense resistors so that an open or short circuit tamper on the loop can be detected and the monitoring centre alerted In this case the connections should be made as shown opposite Note For this feature to work correctly it is essential that the resistors are connected at the contact end of the loop and not the dialler end The monit...

Page 10: ...on and scroll down with the scroll bar on right till you see option for Default All 3 Enter the Default All and confirm the default this will cause the dialler to reboot and will now be defaulted Configuration via touch screen IRIS Touch can be configured directly using the on board touch screen using the supplied stylus Enter the default installer code 111111 and then click Logon You will be prom...

Page 11: ...ing configuration so there is no need to change any settings on the alarm dialler Alarm panel integration e g Honeywell Galaxy RS485 connection Texecom Premier range RS232 TTL connection If you have not already made the changes to the relevant configurations in the panel for the integration and require further details on these configurations then please download the full panel installation manual ...

Page 12: ... option On first entry to the reflash option which could be during installation or maintenance the engineer will be required to change the password as required for EN50136 2 Please record the password on the installation documentation Enter the correct reflash password and the unit will try to connect to the Chiron reflash server and check if a later version is available If a newer version is avai...

Page 13: ...nal block Serial interface to alarm panel RS485 RS232 TTL RS232 x 2 PIN Inputs interface to alarm panel Maximum input voltage range 0V to 24V Input low alarm threshold 1V Input high restore threshold 2V Internal pull up impedance 10K to 3 3V supply Alarm protocols SIA level 1 to 3 Contact ID Fast format Scancom Robofon Dial capture only Tamper detection reporting to monitoring centre Dial capture ...

Page 14: ...SELV suitable for connection to the TNV interface of single line telecommunications equipment such as telephones fax machines etc Power Interface SELV for connection to a DC supply Inputs SELV for connection to alarm output pin Conformance European Directives The IRIS Touch complies with the following European Directives 1999 5 EC Radio Telecoms Terminal Equipment Directive 2006 95 EC Low Voltage ...

Page 15: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0 Page 15 of 16 ...

Page 16: ...nquiries 41 435 080 870 Email sales chironsc com www chironsc com CHIRON SECURITY COMMUNICATIONS AG BAARERSTRASSE 19 6300 ZUG SWITZERLAND The information contained is supplied without liability for any errors or omissions No part may be reproduced or used except as authorized by contract or other written permission The copyright and foregoing restriction on reproduction and use extend to all media...