background image

4

/15

 

 

Starting IRMA MATRIX on the PC via Ethernet 

released

 

 

Rev. 1.2 

 

2016-02 

 

1

 

General 

1.1

 

Symbols / abbreviations used 

 

 

 

"Please note!" 

 

"Information" 

 

 

 

"Instructions" 

 

"Download" 

 

 

 

"See Annex" 

 

"See document on our website" 

M12CAN-CON-03

  iris product designation / name of an IRMA MATRIX component 

sCON

 

Connector for IRMA MATRIX sensors 

Connector (f)

 

 

Female connector 

 

 

Connector (m)

 

 

Male connector 

 

 

x, y 

 

Variable cable executions or variable cable lengths 

XX or Kq 

 

Cable available in 2 different cable qualities  

"Advanced“

 

Name of a window or button  

1.2

 

Brief description  

These instructions describe the steps required for connecting an IRMA MATRIX sensor to 
any PC. Afterwards, a suitable software program enables for example the check of the 
condition on delivery, configuration of the sensor properties, updating of the firmware or 
viewing of the sensor graphic data. Communication between the sensor and the PC is 
effected via Ethernet. 

 

Summary of Contents for DIST500-A

Page 1: ...de Subject to alterations Automatic passenger counting IRMA Infrared Motion Analyser 5th generation IRMA MATRIX Start on the PC via Ethernet Operating Instructions For the service software variants of...

Page 2: ...irst edition 1 2 29 02 2016 VEGI Page 6 changed IP address IP address range Validity Sensors and connectors covered by this document Product Component Product designation Description IRMA MATRIX DIST5...

Page 3: ...tandard connector of the sCON S ETH 22 Kq x y type 12 7 Starting the service software 13 7 1 Before the first run of the service software program 13 7 2 Important at each start of the software 14 7 2...

Page 4: ...m Male connector x y Variable cable executions or variable cable lengths XX or Kq Cable available in 2 different cable qualities Advanced Name of a window or button 1 2 Brief description These instruc...

Page 5: ...24 V power block M12 with M12 connecting cable M12 connector f 5 poles A coded The power block is available as an accessory 2 The following sensor connector combinations can be used for servicing IRMA...

Page 6: ...DP ports must be released for the network architecture 34952 34953 34954 Otherwise there will be no connection 4 Making the IP settings PC The sensor has its own IP address which can be configured In...

Page 7: ...ies In the Local Area Connection Status properties window select the Internet Protocol Version 4 TCP IPv4 by clicking on it see Figure 1 to the left and click on the Properties button For Windows XP 7...

Page 8: ...e 1 on the right 4 For our example please enter IP address 10 0 0 55 Subnetwork mask 255 0 0 0 Please do not make any entries for the Standard gateway or DNS server 4 2 Setting as a second IP address...

Page 9: ...the Add button The input mask TCP IP Address opens see Figure 3 on the left For our example please enter IP address 10 0 0 55 Subnet mask 255 0 0 0 Conclude the entry of the IP address by clicking Add...

Page 10: ...le please switch off the WLAN hardware switch on the PC or deactivate the WLAN symbol in the status bar or deactivate WLAN via the PC operating system via the path Control Panel Network and Internet 2...

Page 11: ...Connect the CAN interface of the sensor M12 male connector type CAN to the M12 female connector type CAN of the Power block item 3 6 The final step is to connect the power block to power supply 1 IRMA...

Page 12: ...nnector type of the switch An adapter can be necessary The most common types are e g SUB D9 RJ45 M12 D coded 1 IRMA MATRIX sensor DIST500 A DIST500 F surface mount or flush mount version 2 Standard co...

Page 13: ...e tool please proceed as follows 1 Mark the program icon on the desktop right click and select Properties The Properties windows opens 2 Click into the input window Target see Figure 6 3 Directly behi...

Page 14: ...uctions for more detailed information 7 2 2 DIST500 Visualization_4 2 0 112 or higher This software program is a tool for the representation of the ongoing counting process and the monitoring range of...

Page 15: ...e reset This can be omitted only if the IP address of the sensors was made as a second IP entry In order to prevent unnecessary PC reboots it has proven successful to restore the previous settings of...

Reviews: