background image

User Manual BMM-1716

 

All technical values are subject for changes w/o further notifications 

 

                                               IRENIS GmbH © 2021

 

Safety instructions 

 
Read the safety instructions carefully before assembling or commissioning the device and ensure that you 
comply with them
 
1.  Installation 

 

Danger: The device may only be installed and started up by competent people (see EN 60065)

 

Danger: The device and the peripheral distribution devices must be earthed properly (potential 
equalization) in accordance with EN 60728-11 before 
Commissioning and remain earthed even when the device is dismantled. 

 

Danger: The device may not be installed on a flammable base (risk of fire)

 

Danger: Only connect the device to a socket that is installed correctly and connected to devices that has 
an earth conductor  
(Depending on Model andUsage). 

 

Danger: Plan the assembly or installation location to ensure that children cannot play with the device and 
its connections.  
There is a risk of electric shock (Danger of death)

 

Danger: Select an assembly or installation location in which fluids or objects cannot get into the device 
under any circumstances (e.g. condensation, water for watering plants, etc.). 

 

Danger: Ventilation slots and refrigeration units are important function elements on the devices. If 
devices have refrigeration units or ventilation slots, you must ensure that they are never covered or built 
over. Also ensure that there is sufficient air circulation around the device.  This prevents possible damage 
to the device and the risk of fire due to overheating. Ensure a minimum of clearance of 20cm between 
the device and other objects. 

 

Danger: The assembly or installation location must allow all connected cables to be laid safely. Cables and 
power supply cables must not be damaged or crushed by any objects. Furthermore, ensure that cables 
are not laid in the immediate vicinity of sources of heat (e.g. radiators, other electrical devices, fireplaces, 
etc.) (Risk of fire)(risk of electric shock danger of death) 

 

Danger: In order to prevent damage to the device, as well as possible subsequent damage (risk of fire)
devices intended for installation on the wall are only permitted to be installed on a level surface and not 
above head height

 

Warning: (Only for optical transmitters and their peripheral distribution devices) Never look directly or 
indirectly into the laser beam. Only connect the device to the power supply once all optical lines are 
connected securely. 

 

Warning: The safety regulations in the relevant current standards EN 60728-11 and EN 60065 must be 
complied with. 

 

Warning: Comply with all applicable national safety regulations and standards. 

 

Warning: The device's mains plug must be easily accessible at all times. 

 

Warning: Follow all instructions in the device-specific operating manual 
2.  Operation 

 

Danger: The device is only permitted to be operated in dry rooms in a non-tropical climate. In damp 
rooms or outdoors, there is the risk of short circuits (risk of fire) or electric shock (danger of death)

 

Danger: Do not insert any objects through the ventilation slot. Risk of electric shock (danger of death)

 

Danger: Do not put any containers filled with liquid (e.g. vases) on the device. There is a risk of electric 
shock (danger of death) or (risk of fire)

 

Danger: No open sources of fire such as burning candles are permitted to be placed on the device (risk of 
fire)

 

Danger: Ensure that there is a clearance of at least 20cm around the device. The device ventilation is not 
permitted to be impaired by covering the 

 

Ventilation openings with objects such as newspapers, tablecloths, curtains, etc. (risk of fire)

 

Warning: Follow all instructions in the device-specific operating manual. 
3.  Maintenance 

Summary of Contents for BLANKOM BMM-1716

Page 1: ...s Anschlussd mpfung Terr 18dB Isolation Entkopplung H V 30dB Return loss Inputs Outputs R ckflussd mpfung 10dB LNB supply voltage LNB Spannung 15 VDC per trunk line je Stammleitung Max LNB supply curr...

Page 2: ...x SAT T network serving multiple Signal Input combinations Kurzbeschreibung Diese u erst kompakte Blankom Satelliten L Band Matrix BMM 1716 verf gt ber einen WEB Controller der von einem Internet Brow...

Page 3: ...echnical values are subject for changes w o further notifications IRENIS GmbH 2021 Application example Master Backup Satellite stations to Headend Applikationsbeispiel Master und Backup Satellitensyst...

Page 4: ...u Network Settings 10 Menu item Software Update Menu Software Update 11 Menu item Device Settings Settings Save Load Settings 12 Saftey and Mounting instructions 18 Montage und Sicherheitshinweise 19...

Page 5: ...provide notification of such revision or change IRENIS GmbH provides this manual without warranty of any kind neither implied nor expressed this includes also any warranties regarding the merchantabi...

Page 6: ...d connection work must be carried out before the unit is connected to the mains voltage supply Observe the safety instructions The SAT IF signals and the terrestrial signal must be fed into the corres...

Page 7: ...et Ethernet 100BaseT SAT A SAT B Terr SAT C SAT D Ground Power 2 Status LED indicates LED green flashes Device setting is running LED green Device ready for operation LED flashes green Red alternating...

Page 8: ...ess of the MATRIX subnet mask 255 255 255 0 IP address 192 168 1 xxx xxx must not be exactly the same one as of the MATRIX devices The digits 0 255 or already used IP addresses are not permitted If a...

Page 9: ...tom of the menu the button Save is located After pressing this button the selected values will be set Location In this menu item the location of the device will be displayed The Location can be edited...

Page 10: ...nagement of the device via web browser may be configured The values of the IP address subnet mask gateway and the management port must be adapted to the local network and individualized see point 8 1...

Page 11: ...a link we will proviode to you upon request never change a running system This should be saved to the PC Notebook that is used to connect to the device NOTE Please follow the update instructions care...

Page 12: ...rview and Load Settings By pressing the button Save in the sub menu Save Settings all settings can be stored on a PC notebook To do this enter a directory and a file name e g settings Matrix Via the s...

Page 13: ...User Manual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021...

Page 14: ...nual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 This is a binary file which can be used for upload to the device Not to review it Reviewing the se...

Page 15: ...6 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 Something for the freaks Load settings likes to get the esm file not the RTF file The user Password can be cha...

Page 16: ...ers in any order and length in the Username field In the field New Password enter the new password with at least 6 digits consisting of letters numbers or special characters in any order A green check...

Page 17: ...User Manual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 Now its time to adjust your Inputs to the outputs And SAVE it Ready thats all...

Page 18: ...User Manual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 Saftey and Mounting instructions...

Page 19: ...User Manual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 Montage und Sicherheitshinweise...

Page 20: ...lligkeit im Frequenzband Ripple in F range See below Abzweigd mpfung TERR 19 2dB Attenuation between outputs See below Entkopplung H V 25dB min Isolation H V See below Anpassung R ckflussd mpfung 10 d...

Page 21: ...User Manual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 Frequency Range TERR receiver output port Frequenzgang TERR output...

Page 22: ...User Manual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 Frequency Range SAT User Ports Out Frequenzgang SAT Outputs...

Page 23: ...User Manual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 Isolation Schirmung H V...

Page 24: ...User Manual BMM 1716 All technical values are subject for changes w o further notifications IRENIS GmbH 2021 ISOLATION Schirmung TERR...

Page 25: ...6 31 5 3E 04 17 77 31 75 7 08 6 7E 04 18 78 30 75 7 94 8 4E 04 19 79 29 75 8 91 1 1E 03 20 80 28 75 10 00 1 3E 03 21 81 27 75 11 22 1 7E 03 22 82 26 75 12 59 2 1E 03 23 83 25 75 14 13 2 7E 03 24 84 2...

Page 26: ...841 49 109 0 25 281 84 1 059 50 110 1 25 316 23 1 333 51 111 2 25 354 81 1 679 52 112 3 25 398 11 2 113 53 113 4 25 446 68 2 660 54 114 5 25 501 19 3 349 55 115 6 25 562 34 4 216 56 116 7 25 630 96 5...

Page 27: ...gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le re...

Page 28: ...ust not be damaged or crushed by any objects Furthermore ensure that cables are not laid in the immediate vicinity of sources of heat e g radiators other electrical devices fireplaces etc Risk of fire...

Page 29: ...power and operated when the mains adaptor cover is installed This also applies when you clean the device or work on the connections Danger Repairs on the device may only be carried out by a specialis...

Page 30: ...rgendwelche Gegenst nde besch digt oder gequetscht werden Es ist dar ber hinaus unbedingt darauf zu achten da Kabel nicht in die direkte N he von W rmequellen verlegt werden z B Heizk rper andere Elek...

Page 31: ...Ger t darf nur mit montierter Netzteilabdeckung an Spannung angeschlossen und betrieben werden Dies gilt auch wenn Sie das Ger t reinigen oder an den Anschl ssen arbeiten Gefahr Reparaturen am Ger t s...

Page 32: ...with these instructions will result in voiding of warranty cover Die Ger te d rfen nur in trockenen Innenr umen montiert werden Nicht auf oder an leichtentz ndlichen Materialien montieren The equipmen...

Page 33: ...sgefahr Free circulation of air must be possible to discharge the heat emitted by the unit Risk of overheating Zul ssige Umgebungstemperatur 20 bis 50 C Permissible ambient temperature 20 to 50 C Impo...

Page 34: ...tion de ces syst mes rel ve de la responsabilit de l installateur et ou de l exploitant En particulier il convient de respecter les r glementations et directives applicables dans les pays respectifs p...

Reviews: