8
Introduction
This guide provides the basic information needed to operate an Iradion 1625 Laser. This
laser is designed for use while integrated within a system and is not designed to meet
CDRH requirements as a stand-alone product. As such, the user needs to be aware of
certain requirements before use.
CDRH
This is an OEM laser component that has been designed for integration into a functioning
laser system. As a stand-alone device, it cannot be turned on and therefore does not
incorporate all of the safety features required by the Center for Devices and Radiological
Health (CDRH). Provisions for the incorporation of the safety features are available, and
the user is expected to apply them and fully comply with all CDRH requirements.
Available Safety Features
The following safety features are available as electronic signals on the rear panel
interface:
Interlock
Upon contact closure, allows the system to operate.
An open connection will disallow the laser from firing.
Key switch
Upon contact closure, allows the laser to fire after
imposing a 5-second delay. (Key switch function is
program version dependent.)
Power up in Fault
Requires the key switch to be cycled. (Program
version dependent.)
Lase signal
Output signal indicating the laser is firing.
Fault signal
Output signal indicating the malfunction of an internal
component or the electronics.
Indicator lights
DC Power, Temp Warning, Interlock, Fault, Ready,
Lase