1 Safety and General Information

 

 

The  information  in  this  document  is  subject  to  change  without  notice,  as 

standards,  specifications,  and  designs  change  from  time  to  time,  please ask 

for confirmation of the information given in this publication.

 

  

 CAUTION

 

 

 

Consulting  the  dealer  is  required  before  using  for  below  equipment.  Its 

application,  configuration,  management  and  maintenance  must  be  specially 

considered and designed.

 

 

 

Medical equipment which is directly related to patients’ life

 

Equipment which may endanger personal safety

 

Non-qualified electricians are forbidden to open the case due to hazard of 

electrical shock. And only qualified electricians can make wiring or maintain 

the UPS due to naked electrical parts at the external wiring section.

 

 

The product is not intended to be used alone for users, it is designed for 

special application. Separated fire-retardant enclosure or casing for 

protection is required.

 

 

The product must be grounded firmly when it is connected to the utility 

power.

 

 

Output short-circuit is not allowed for the UPS in case of connecting to the 

utility power.

 

 

Avoid a short circuit on positive and negative polarities of battery, otherwise 

it can lead to electric shocks or a fire.

 

 

Cut off the electricity supply immediately when the UPS operates 

abnormally, and contact your dealer.

 

 

 

 

~ 1 ~

 

Summary of Contents for LiftUPS-1k0-3LED-BC60

Page 1: ...1 07 2020 www ips ups eu LiftUPS manual EN R1 LiftUPS 1k5 3LED BC60 LiftUPS 1k5 6LED BC60 LiftUPS 1k5 LCD BC60 LiftUPS 1k0 3LED BC60 LiftUPS 1k0 6LED BC60 LiftUPS 1k0 LCD BC60 ...

Page 2: ...ualified electricians are forbidden to open the case due to hazard of electrical shock And only qualified electricians can make wiring or maintain the UPS due to naked electrical parts at the external wiring section The product is not intended to be used alone for users it is designed for special application Separated fire retardant enclosure or casing for protection is required The product must b...

Page 3: ...put voltage selectable Mains power mode synchronized with utility power Output waveform Battery mode square wave Mains power mode synchronized with utility power Inversion efficiency Max 87 IT equipment Yes Half wave load 50 rated load Inductive load No BATTERIES Rated voltage 60 Vdc Battery capacity 12 V 5 4 9 Ah Charging current 1 A Equalizing charge Single battery 14 2 Vdc default voltage 13 6 ...

Page 4: ...excessive low battery Overload times 110 for 120 s 125 for 60 s 150 for 10 s Mains mode 200 for 1 s Overload times 110 for 60 s 125 for 5 s 150 for 1 s Battery mode Communication No interface Panel display 6 LED 3 LED LCD OTHERS Operating temperature 0 45 Operating humidity 0 95 no condensing Altitude 1000 m Above 1000 m derating 1 for each additional 100 m IP rating IP20 Cooling Forced air coolin...

Page 5: ...to the physical model 3 1 Panel Features 6 LED Indicators Alarm indicator light red Charging indicator light yellow Output indicator light green Load indicator lights green Power ON OFF button 3 2 Panel Features 3 LED Indicators Output indicator light green Charging indicator light yellow Alarm indicator light red Power ON OFF button 4 ...

Page 6: ...y mode Output voltage Load capacity Battery capacity 3 4 Rear Panel Features Fan guard filter AC overcurrent protector Input live wire interface Input neutral wire interface Input earth wire Interface Output neutral wire interface Output live wire interface Battery positive interface Battery negative interface 5 ...

Page 7: ... mounting bracket to both sides of the case using screws Attach the UPS to the mounting bracket based on the fixed distance between holes Mounting 1 Mounting 2 Fixed distance between holes A 40 mm B 220 mm C 180 mm 2 Connect devices according to the UPS connection diagram 6 ...

Page 8: ... seconds Low battery alarm red Flash once per 0 5 seconds Battery mode Illuminated Floating charge of battery Charging Extinguish Battery mode system faults Flash once per 0 5 seconds Charger failure indicator light Flash once per 1 second Equalizing charge of battery yellow Flash once per 5 seconds Battery failure disconnected Output Illuminated There is output for the UPS There is no output for ...

Page 9: ...the fault code The output indicator light stands for the first number If the indicator is lit indicates 1 if the indicator extinguishes indicates 0 For example the following picture shows that the fault code is 1001 View the last two numbers of the output voltage displayed on the LCD panel to check the fault code For example the following picture shows that the fault code is 28 8 ...

Page 10: ...he air vents is blocked and over temperature the fan is working properly UPS output short Check the load type whether the load 1001 45 49 is seriously overloaded and whether circuit the load is short circuited UPS output 1010 50 54 Check the load and use it after overload reducing the load UPS output Check the load type whether the load 1011 55 59 is seriously overloaded and whether overcurrent th...

Reviews: