YLS-K
Restart after changes
All changes to the LaserNet settings under this menu
item will only be applied after a restart of the laser.
ð
Turn the key switch on the front side of the
laser to the OFF position and wait 5 seconds be-
fore turning the key switch back to TEST or RO-
BOT.
ð
After switching the laser on again, check
whether the changed settings were applied cor-
rectly.
Laser\ Advanced
Settings
Automatic Switching OFF
In the submenu
Advanced settings
, you can set the laser emission time
of the laser. To do this, enter the desired emission time in the input field
Max. Emission Time
(see figure below). The laser emission will stop af-
ter the configured time has elapsed, starting from the time at which the
status
Emission enabled
was activated. If you activate the
De-energizing
of power supplies
field, the main power supply will also switch off as
soon as the laser emission stops. The
Automatic switch-off
function is
deactivated if you enter zero (0) seconds into the input field
Max. Emis-
sion Time
.
Figure 42:
Advanced settings
| LaserNet software