| Assembly and installation
44
YLS-K
5.1
Space requirements and room conditions
NOTICE
Product damage due to freezing
Freezing water in water lines can cause damage to
the product.
ð
Do not set up the product in areas at risk to
freezing temperatures!
Relevant information
The dimensions as well as the weight and climate in-
formation for the product can be found in the sup-
plied specifications.
Installation
Observe the following points for installation of the product:
ð
Select the installation position such that access to the product
from all sides is guaranteed. A minimum distance of 1 m must be
maintained on all sides.
ð
Note the weight of the product as well as the temperature and
humidity limits when selecting the installation site.
ð
Make certain that the product is only installed on level, paved
surfaces to ensure the stability of the product.
ð
Install the product such that no damage can result from internal
traffic or transports.
5.2
Supply connections
ð
Make sure that all supply connections required for operation of
the product are available and usable.
5.2.1 Supply voltage
The product requires a voltage supply of 3 x 400 VAC at 50 Hz or 3 x
460 VAC at 60 Hz (see the table below). The connection has four poles
(L1, L2, L3, clockwise phase sequence and PE).
Additional information regarding electrical connection values can be
found in the supplied specifications.