background image

 

 

 

MANUAL

 • Subject to alteration! Version: December 2013 

 

ipf electronic gmbh

 • Rosmarter Allee 14 • 58762 Altena 

 Tel +49 2351 9365-0 

 [email protected] • 

www.ipf-electronic.com 

 

 

1

 

   

 

 

 

OT15 series 

 

Diffuse-reflection sensors 

 
 
 

Installation and environment 

Coatings on the optics impair the function. Please install the device in such a way that no dust can be deposited or 

liquids can get onto the optics. The device should be accessible for cleaning.  

From time to time the optics should be cleaned with a soft cloth moistened with alcohol or soapy water. 

 

 

Cable 

The PVC connecting cable of the fixed cable devices is not suitable for environments containing oil or solvents or for 

applications in which the cable is frequently moved.  

In such cases the use of a connector device with an ipf-Sensorflex cable socket is recommended. 

 

 

Adjustment 

With the built-in potentiometer the sensitivity and thus the switching distance can be changed. When delivered the 

device is set to the maximum value. The switching distance is reduced by turning it counterclockwise. The full adjust-

ment range of the potentiometer is 12 turns.  

Safe operation is ensured if the output switches (light-on mode) when the object is detected and the green function 

LED lights up in addition to the yellow switching status LED.  

If only the yellow LED lights up when the output is switched, either the sensitivity is set too low, the selected switching 

distance is too large, or the optics are dirty.  

When the green LED lights up, the alarm output of the OT150700 and OT150770 versions is switched on simultaneously. 

 

 

Note 

The devices react to the intensity of light reflected from any object. The specification of the nominal switching distances 

is based on white paper with a surface of 200 x 200mm. With more reflective materials (e.g. polished aluminum) the 

maximum switching distance increases. With low reflective materials (e.g. black rubber) the nominal switching distance 

cannot be reached by far. 

  

 