Technical Documentation
opti-check
v2.8.2-K11
302/332
ipf electronic GmbH
Lüdenscheid, Germany
15.5.2.3 Group: Result data
This group is used to transfer the result data from job processing. The results datagram is configured during
job creation in the
Application Suite
in the step
Configure interfaces → Output process interface
.
Variants are available with payload capacities of 4/8/16/32/64/128/256/512 bytes. You should choose the
smallest possible variants for the volume of data you expect to handle. An unnecessarily large selection
reduces overall system performance.
The data corresponds to response to the "GD" command from the classic process interface.
Data element
Direction
Type
Length
(byte)
Description
Actual length of
the result data
Device
PLC
UINT16
2
Length of data actually used in
ResultData
Result data
(<n> byte)
Device
PLC
OCTET-
STRING
4/8/16/32/64/128/256/512 Result data for job processing (data
length corresponds with the selected
module)