13.6.1 Binary job selection
For the device a maximum of four digital inputs are available for job selection.
It is possible to quickly switch between jobs 1 to 16 in this way.
The allocation of the levels to the selected job is as follows:
Binary job
selection -
Bit
0
Binary job
selection -
Bit
1
Binary job
selection -
Bit
2
Binary job
selection -
Bit
3
Job 1
Low
Low
Low
Low
Job 2
High
Low
Low
Low
Job 3
Low
High
Low
Low
Job 4
High
High
Low
Low
Job 5
Low
Low
High
Low
Job 6
High
Low
High
Low
Job 7
Low
High
High
Low
Job 8
High
High
High
Low
…
Job 16
High
High
High
High
NOTE
Please observe that this table relates to the configuration of the inputs as "active high". If
you have configured an input as "active low", you must invert the specified levels for this
input in the overview.