13.2 Timing when an external trigger is used
The sequence of the individual signals and their designation are indicated in the diagram below:
Signal
Full resolution
Reduced resolution
(device dependant)
min.
max.
min.
max.
Trigger-exposure time delay T
1
20
s
plus preset trigger delay
Exposure time T
2
Internal illumination
1
35
s
10 ms
35
s
5 ms
External illumination
35
s
1
/ 10
s
2
65.5 ms
35
s
1
/ 10
s
2
65.5 ms
Flash controller
2
10 µs
1 ms / 65.5 ms
10
s
1 ms
Image acquisition T
3
16 ms
20 ms
8 ms
11 ms
Output time (min / max) T
4
20 ms
11 ms
Run-up output T
5
50
s
2 ms
50
s
2 ms
Result retention time T
6
1 ms
1 s or next
result
1 ms
1 s or next
result
)
1
Devices with integrated lenses )
2
Devices with interchangeable lenses
Following image acquisition, the
Camera Ready
signal is deactivated. The
Camera Ready
signal is activated
again at the end of image acquisition and another image acquisition operation is possible immediately.
The Pass/Fail signal then switches at the set output time even if additional analyses have already been
performed. The
Result valid
signal is active during this time.
NOTE
If you have connected an encoder, you may set the output time and duration as a
distance.
In addition, you can specify an "output run-up" in milliseconds to activate the Pass/Fail
signal before reaching a specific position. This option is available if an exact output time
has been specified and this is specified as a distance.