AO000219 

Safety systems 

Accessories 

 
Dimensions 

26,6x44x81 (not mounted) 

 

 

 
 

 

 

 

 

 

 

 

Aluminium housing 

 

Laserclass 2 

 

Installation performed through one of two lateral grooves  

  of the safety light curtain housing 

 

Mounting brackets in storage box 

 

Voltage supply with batteries 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description 

äter noch möglich. 

Thanks to its completely new housing and fixing system 

AO000219 laser pointer can be installed in all safety light 

curtains profiles of OY32, OY35 and OY36 series. Thanks 

to a specially designed CAM fixing  equipment the laser 

pointer can be inserted into one of the two lateral grooves 

either from the top or from the side, depending on which 

kind of fixing brackets have been used to mount the safety 

light curtain (standard “L” or TOP-BOTTOM Rotating ones). 
One top and one lateral fixing brackets, together with two 

tightening knobs, allow to adjust AO000219 laser pointer’s 

position in both transversal and longitudinal directions and 

to have it constantly centred respect light curtain’s optical 

axis, independently from housing width..

 

Typical applications 

 

The AO000219 laser pointer is advised to be used to ease transmit-

ter and receiver mechanical alignment process in the following 
installation conditions: 

  Mutli-beam body/access protection safety light curtain whose ope-

rating distance is more than 25m; 

  Mutli-beam body/access protection safety light curtain installed 

with deviating mirrors to perform perimetric protections; 

 Finger or hand protection safety light curtains installed with 

deviating mirrors to protect different sides of a machine. 

 

  Laser-Pointer 

  for OY32, OY35, OY36 

 

 

 

 

 

 

 

 

 

   

Summary of Contents for AO000219

Page 1: ... the side depending on which kind of fixing brackets have been used to mount the safety light curtain standard L or TOP BOTTOM Rotating ones One top and one lateral fixing brackets together with two tightening knobs allow to adjust AO000219 laser pointer s position in both transversal and longitudinal directions and to have it constantly centred respect light curtain s optical axis independently f...

Page 2: ... driver remove the 2 TSP UNI 7688 M2 5x8 screws from bottom closing cap then remove it to have access to the battery box put off the battery box extract the two batteries and replace with new ones Place the battery box in its place close with the cap and firmly tighten the screws Exhausted batteries are designated for separate collection at an appropriate collection point Do not dispose of as hous...

Page 3: ... with TOP BOTTOM rota ting brackets Top mounting Insert the b ensemble inside the lateral groove keeping the couple of cams in vertical position Fig 1 until you ve reached the right po sition Fig 3 Side mounting Insert the b ensemble abutting on the curtain side corresponding to the lateral groove Keep the couple of cams in horizontal position Fig 2 and after they entered the groove rotate them of...

Page 4: ...ate the unit allowing angle adjustment along the vertical unit axis If necessary the inclination of the floor stand can be changed by simply mounting washers under the base 2 Repeat this procedure inserting the pointer in the lower part of the emitting unit if necessary repeat this proce dure unit the desired result is obtained 3 Insert the laser pointer in the upper part of the receiving unit and...

Reviews: