LD11
The status of 11
th
port or 23
rd
port
ON (Blue) : 11
th
port Use
ON (Yellow Green) : 23
rd
port Use
ON (Blush white) : 11
th
and 23
rd
port Use
OFF: Idle
LD12
The status of 12
th
port or 24
th
port
ON (Blue) : 12
th
port Use
ON (Yellow Green) : 24
th
port Use
ON (Blush white) : 12
th
and 24
th
port Use
OFF: Idle
LD13
ACT, Activation or Normal
Operating
Blink (Blue Color)
LD14
In use
ON: Ch. Use,
OFF: All channels Idle
4.4.4.2
DTIBC Installation
The DTIBC has no switches or connectors that are field useable. The DTIBC can be installed in any universal
slot of any KSU; the 1st slot of the BKSU is for the MPB only.
1)
Assure Power is OFF
2)
Slide the DTIBC in the guide rails of the desired slot.
3)
Tighten thumbscrews to hold the board firmly in place.
4.4.4.3
DTIBC Wiring
Each DKT port is terminated to a pair in the RJ21 connector. DKT 1 is terminated at pair 1, DKT 2 is
terminated on pair 2, etc. to the number of ports (12 or 24) on the DTIBC.
Referring to the pin-out chart below,
Wire each DKT pair on the RJ21 connector to the DKT termination point using UTP cable. The
maximum total wire length is 500M/1.6Kft of 22 AWG or 330M/1Kft of 24 AWG wire. For information
on wiring the DKT, refer to section 5.1.2.1.
Tag or number wiring for maintenance.
Table 4.4.4.4-1 DTIBC Pin-out Chart
CONNECTOR
PIN(VT)
PIN(VR)
COLOR CODE
SLIB PORT
RJ21
1
26
1
2
27
2
3
28
3
4
29
4
5
30
5
6
31
6
7
32
7
8
33
8
9
34
9
10
35
10
11
36
11