background image

19 

 

Generic   Alarm   Panel   Wiring   and   Programming   

Generic Keybus & Tip/Ring wiring 

 
 

Generic Alarm Panel Programming 

 

Program the panel Phone Number into the panel 

 

Program the Customers Account Number into the panel 

 

Program Reporting codes into the panel 

 

Program panel to transmit in Contact ID format 

 

For interactive (Keyswitch) wiring and programming see the next 
section.

   

Generic Control 

Panel

TIP RING

Red

+

Black

-

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Tip

Ring

+ Pos

- Neg

Y / Tx

G / Rx

Tx

Rx

B

A

TXD

RXD

Z1 out

Z2 out

RS-232

RS-485

PC-Link

Power

BAT-CDMA

Telco Side

Summary of Contents for BAT-CDMA

Page 1: ...1 www ipdatatel com Universal CDMA Broadband Alarm Transceiver User s Guide Installation and Operating Instructions ...

Page 2: ...D BLK YEL GRN DSC Control Panel 3 4 5 6 Pos Neg Y Tx G Rx Power Pos Com Data GE Control Panel 3 4 5 6 Pos Neg Y Tx G Rx Power Data in Data out Vista Control Panel QUICK REFERENCE GE Programming on GE NetworX Section Device 0 BAT as Sole Communicator Location 0 Enter the Phone Number Location 1 Enter Account Number Location 2 Enter 13 for Contact ID VISTA Programming on Vista Section BAT as Sole Co...

Page 3: ...nection 8 Power Connection 8 Basic Programming 8 Full Virtual Keypad Programming 8 Troubleshooting Diagnostic Information 8 Validating the Installation 9 Wiring Programming for Popular Panels 9 DSC Panel Wiring and Programming 10 Vista Panel Wiring and Programming 14 GE Panel Wiring and Programming 17 Generic Alarm Panel Wiring and Programming 19 Generic Keyswitch Wiring and Programming 20 Support...

Page 4: ...l ipDatatel s uDownloader software enables remote management of Honeywell DSC and GE NetworX alarm panels that are connected to the BAT CDMA Key Features Broadband Internet Connectivity The BAT CDMA replaces outdated conventional phone lines to provide high speed IP alarm monitoring transmissions over the Internet By capturing the data transmission off the alarm control s digital dialer output the...

Page 5: ... uDownloader currently supports Honeywell Compass GE NetworX DL900 and DSC DLS IV DLS 5 ipDatatel s uDownloader software is available for download at www alarmdealer com in the Dealer Resources section Virtual Keypad Access Your customers can operate their alarm system using ipDatatel s ipFob app using their smartphone or web browser ipDatatel s ipFob gives the customer a virtual keypad to their a...

Page 6: ...l Technical Support 13110 Southwest Freeway Sugar Land TX 77478 Installation General Considerations Before installation your BAT CDMA must also be setup using the dealer Branded Portal www alarmdealer com The BAT CDMA should be installed securely in the supplied plastic housing and be mounted beside your alarm control panel Proximity to the hard wired Ethernet Internet connection should be taken i...

Page 7: ...ou can search for it by MAC address Follow other registration steps and options as found on this page then click Save to complete the registration Locating and Installing the BAT CDMA The BAT CDMA connects to the alarm panel s power connections Telco virtual keypad bus if available and keyswitch connections optional The BAT CDMA should be connected to the Internet via a hard wired RJ45 Ethernet In...

Page 8: ...hone service to the panel general programming for the control is limited to configuring the signal format as Contact ID as well as inputting a telephone number to dial In our case the actual telephone number does NOT matter and is NOT used in the signal delivery process Full Virtual Keypad Programming For panels that are Interactive Ready See Supported Panels section the following programming will...

Page 9: ... that virtual keypad functionality works through alarmdealer com or the ipFob mobile app Insure that alarm signals reach your central station Wiring Programming for Popular Panels The following pages are organized by Alarm Panel type Wiring and programming instructions are given for Digital Security Control DSC Alarm Panels Ademco Honeywell Vista Alarm Panels GE NetworX Alarm Panels ...

Page 10: ... and Programming DSC Keybus Tip Ring wiring RING TIP RED BLK YEL GRN DSC Control Panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Tip Ring Pos Neg Y Tx G Rx Tx Rx B A TXD RXD Z1 out Z2 out RS 232 RS 485 PC Link Power BAT CDMA ...

Page 11: ... downloader functionality with ipDatatel s Universal Downloader uDownloader software DSC PC Link Wiring DSC PC Link 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Tip Ring Pos Neg Y Tx G Rx Tx Rx B A TXD RXD Z1 out Z2 out RS 232 RS 485 PC Link Power BAT CDMA ...

Page 12: ...le Communi cator BAT as Failover w Add l Communi cation Device BAT as Dual Reporting w Add l Communi cation Device Code Summarization 015 Disable Option 7 If GSM Disable Option 7 If Phone Line Enable Option 7 If GSM Disable Option 7 If Phone Line Enable Option 7 Option 7 turns on off telephone line supervision 167 Set 060 Seconds Set 060 Seconds Set 060 Seconds Sets T Link acknowledgement delay to...

Page 13: ...ephone 2 option 2 and alternate communi cations option 5 375 Enable Option 1 Enable Option 1 5 Enable Option 1 2 5 Options to turn on off maintenance for telephone 1 option 1 telephone 2 option 2 and alternate communications option 5 376 Enable Option 1 Enable Option 1 5 Enable Option 1 2 5 Options to turn on off testing for telephone 1 option 1 telephone 2 option 2 and alternate communications op...

Page 14: ...nd Programming Vista Keybus Tip Ring wiring 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Tip Ring Pos Neg Y Tx G Rx Tx Rx B A TXD RXD Z1 out Z2 out RS 232 RS 485 PC Link Power BAT CDMA TIP RING Data in Data out Vista Control Panel ...

Page 15: ...ing in Contact ID it will send signals Recommended Programming on Vista BAT as Sole Communicator Section For BAT as Sole Communicator Code Summarization 41 Enter Phone Number 43 Enter Account Number 49 Enter 5 For All Communications to BAT 54 Enter 0 No Delay Between Communicators 55 Enter 0 Phone Line Communicates First 65 66 Enter 1 If you want Opening Closing Reports 193 Enter 1 0 Enable to tur...

Page 16: ...er Enter Account Number This is the central station account number 49 Enter 5 Please refer to panel manual for your particular application requirements Please refer to panel manual for your particular application requirements Dual Reporting Setting to 5 sends all reporting to both primary and secondary 54 Enter 0 Enter 2 Enter 0 The time it takes for the communicator to switch from primary to seco...

Page 17: ...ring and Programming GE Keybus Tip Ring wiring 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Tip Ring Pos Neg Y Tx G Rx Tx Rx B A TXD RXD Z1 out Z2 out RS 232 RS 485 PC Link Power BAT CDMA T R Pos Com Data GE Control Panel ...

Page 18: ...olled with the control panel when the panel exits programming mode The BAT registers as a keypad and a communications device on addresses 240 and 76 respectively All signals are read directly from the panel memory so any call directions and or reporting codes programmed are specifically for other communication devices such as the panel dialer For Central Station monitoring the Account Number for t...

Page 19: ...rs Account Number into the panel Program Reporting codes into the panel Program panel to transmit in Contact ID format For interactive Keyswitch wiring and programming see the next section Generic Control Panel TIP RING Red Black 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Tip Ring Pos Neg Y Tx G Rx Tx Rx B A TXD RXD Z1 out Z2 out RS 232 RS 485 PC Link Power BAT CDMA Telco Side ...

Page 20: ...nel will be used to signal to the BAT Y Tx terminal that the panel has entered Arm Disarmed State The Z1 output on the BAT will be used as a key switch connecting to a zone terminal on the alarm panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Tip Ring Pos Neg Y Tx G Rx Tx Rx B A TXD RXD Z1 out Z2 out RS 232 RS 485 PC Link Power BAT CDMA PGM Z1 Generic Panel Keyswitch Wiring Z2 Z3 ...

Page 21: ...l state conditions Reference the alarm panel installation manual for details on your specific installation Ademco General Concept 56 program zone as type 77 80 Menu LED Outs Program 17 and 18 zone type 78 and 79 DSC PowerSeries General Concept Program zone as 22 PGM Output 6 DSC Alexor General Concept Wiring Y Tx I 01 G Rx I 02 6 2k ohms resistor from Y Tx Programming Section 009 06 22 Section 013...

Page 22: ...ista 128FB 1 0 Vista 128FBP 2 0 Vista 128FBPE 1 0 Vista 128SIA 2008 Vista 15 2 Vista 15CN 2 6 Vista 15P 2 6 Vista 15PCN 2 6 Vista 15PSIA 4 0 Vista 20P 2 6 Vista 20PCN 2 6 Vista 20PI 5 Vista 20PS 2 6 Vista 20PSIA 4 0 Vista 21IP 1 0 Vista 21IPSIA 1 0 Vista 32FB 1 0 First Alert FA130 2 6 First Alert FA148 2 6 First Alert FA168 2 6 ADT Safewatch Pro 3000 3000EN 2 6 ...

Page 23: ... 4V2 V2 NX 6V2 V2 NX 8V2 V2 NX 4V1 V1 NX 6V1 V1 NX 8V1 V1 For non supported panels Bridge 12 VDC to Y TX Terminal with any type of radial resistor with a value of 2 7k to 10k as a weak pull up Note Any Panel not on this list is supported as long as it does Ring Tip and transmits Contact ID If the panel has the ability to use a Dedicated Open Zone that acts as a Keyswitch you can Arm Disarm from th...

Page 24: ... have no liability or obligation under this Limited Warranty or otherwise for merchantability or fitness for any particular use nor shall it extend its Limited Warranty if the product is altered or improperly installed repaired or serviced There are no warranties express or implied that extend beyond those contained within this document In no case shall Seller be liable to person or entity for any...

Page 25: ...accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio f...

Page 26: ...une installation résidentielle Cet équipement génère utilise et peut émettre des fréquences radio et s il n est pas installé et utilise en conformité avec les instructions peut causer des interférences nuisibles aux communications radio Cependant il n existe aucune garantie que des interférences ne se produiront pas dans une installation particulière Si cet équipement provoque des interférences nu...

Page 27: ...27 Circuit Board Details ...

Page 28: ...es CDMA 1x 800 MHz 1900 MHz Power Externally provided 12v DC Environmental Temperature Range 30 to 70 C 22 to 158 F Humidity 0 to 95 non condensing Physical Height 7 05 inches Width 4 45 inches Depth 1 5 inches IPD BAT CDMA MAN REV 2 0 ...

Reviews: