CAUTION:
The device must be de-energized. The change of a battery requires ESD safety
measures to avoid charge transfer to the circuit board and system components.
Please perform the exchange only on an earthed and conductive surface when
using an antistatic wrist strap!
Battery replacement:
1. Disconnect the embedded controller from mains; disconnect data lines.
2. Dismatle
the device from the 19” rack.
3. Unscrew and lift the housing cover by loosening the corresponding nine screws. It is
recommended to use a Torx screwdriver of size T10.
4. Pull the old battery out of the battery holder.
5. When inserting the new battery, make sure the polarity is correct (see polarity marking on the
battery socket).
6. The embedded controller can be put back into operation after the correct installation.
Figure 9: Battery
Caution: When replacing the battery, pay attention to the polarity of the battery!
2.4.8
Power Supply
The SEC3ER must be connected to a voltage of 230 V AC or 115 V AC via a standard IEC cable. For
further information, see chapter 4 Technical data sheet.
CAUTION:
Before opening the device, it is mandatory to switch the device voltage-free!