background image

 

Walter-Bouhon-Strasse 4 
90427 Nuremberg 
Germany 

Edition October 2021 

Version 3.1 

Phone: 
Fax: 
Internet: 
Email: 

+49 911 18 07 91-0 
+49 911 18 07 91-10 

https://www.ipcomm.de

 

[email protected] 

 

 

Industrial PC 

IPC191I7 

General 

Operating, Maintenance and Installation 

Manual

 

Hardware Platform 

Gateway

 

 

 

Summary of Contents for IPC191I7

Page 1: ...Germany Edition October 2021 Version 3 1 Phone Fax Internet Email 49 911 18 07 91 0 49 911 18 07 91 10 https www ipcomm de info ipcomm de Industrial PC IPC191I7 General Operating Maintenance and Insta...

Page 2: ...RS 232 Interfaces 5 2 2 3 8 Port RS 232 Serial Interface Card RS 232 interface for remote communication 5 2 2 4 Ethernet Interfaces 6 2 2 5 CFast Memory Card 6 2 2 6 CMOS Lithium Battery 7 2 2 7 CPU L...

Page 3: ...espect to the industrial PC will be invalid in the event that Operation servicing and maintenance are not carried out accurately according to the instructions repairs are not carried out by our person...

Page 4: ...ny Before and after a 48 hour burn in test each device must run through a complete function test The housing has an excellent air flow for maximum heat dissipation Important for the selection of our c...

Page 5: ...slot 2 main power supply input keyboard 2 x display port DVI 4 x USB PCIe 8x slot 1 Figure 2 overview interfaces Figure 3 8 Port DB9 male connector cable 2 2 Hardware Components 2 2 1 Mainboard The M...

Page 6: ...d surge voltage we recommend the use of our 4 kV isolated RS 232 isolator The used RS 232 transceivers have ESD protection up to 15 kV The isolator was tested according to EMC guidelines and climatic...

Page 7: ...ice i e for storing the operating system the applications and configuration data As a result the disadvantages involved with the use of a rotating hard disk are avoided thus improving the reliability...

Page 8: ...cause of this the process should be carried out only by experienced electronic engineers The device must be completely disconnected from any power supply Before opening please push the power button wi...

Page 9: ...voltage The input voltage of the respective device is labeled on top of the housing see Figure 1 2 2 8 1 AC Power Supply By using AC voltages a specific power supply cable see figure below is supplied...

Page 10: ...sing DC voltages only a male connector is supplied This connector has to be used By connecting the cable with the male connector the correct polarity must be kept The wire cross section must be at lea...

Page 11: ...ottom auto COM8 DB9ST ttyS8 PCIe 8x slot bottom auto COM9 DB9ST ttyS9 PCIe 8x slot bottom auto COM10 DB9ST ttyS10 PCIe 8x slot bottom auto COM11 DB9ST ttyS11 PCIe 8x slot bottom auto COM12 DB9ST 3 2 V...

Page 12: ...7L xyz2 2 x See chapter 5 Nomenclature of IPC191I7 Item Code Assembly Linux Device I O Port IRQ Label Connector mainboard ttyS0 3F8 4 COM1 chassis rear DB9ST ttyS1 2F8 3 COM2 chassis front DB9ST eth0...

Page 13: ...on max 100 W depending on the used type CE UL 60950 1 EN 60950 1 IEC 61850 3 Power Supply DC optional Fanless 9 32 V DC Hold up time 50 ms Switch on delay 100 500 ms Power consumption max 70 W dependi...

Page 14: ...Handling Static Wear Leveling System ECC Very short access time Mass storage in removable frame optional SATA 2 5 SSD or HDD Supported Operating Systems Linux Optical Drive optional CD DVD writer with...

Page 15: ...lines Surge Immunity IEC 61000 4 5 2014 AC Power Supply 4 kV line ground 2 kV line line DC Power Supply 2 kV line ground 1 kV line line Conducted RF IEC 61000 4 6 2014 Severity Level 10 Vrms Power Su...

Page 16: ...Value Description A 85 264 V AC B 24V DC C 30 120 V DC RAM Value Description I 8 GB J 16 GB S 32 GB CFast1 Value Description F 4 GB H 16 GB I 32 GB J 64 GB SSD1 Value Description S4 120 GB S5 150 GB P...

Page 17: ...Subject to alterations Version 3 1 IPCOMM GmbH 16 Industrial PC IPC191I7 Walter Bouhon Strasse 4 Copyright IPCOMM GmbH 2021 90427 Nuremberg All rights reserved Germany 6 IPC191 CAD Chart...