background image

The IOTA IQ-TURBO Charge Controller installs 
by simply plugging the IQ cord into the Dual Volt-
age jack located on the DLS* (Refer to Figure A). 
The IOTA IQ-TURBO circuitry is then automatically 
engaged. Note: the cord provided is specifically de-
signed for use with the IOTA IQ-TURBO. Do not use 
the IOTA IQ-TURBO with any cord other than one 
supplied with the unit.

Smart Charge Controller 

OWNER’S MANUAL 

The 

IOTA IQ-TURBO 

Charge Controller is designed for rapid automatic charging control for DLS 

Battery Chargers with flooded lead acid battery applications, providing enhanced battery charging 
and maintenance. The IOTA IQ-TURBO allows the DLS Charger to deliver an enhanced Bulk 
charge to replenish batteries quickly, in addition to providing Absorption, Float, and Maintenance 
cycles. Multi-stage charging with the IQ-TURBO increases the charging capacity of the DLS 
charger, decreases the charge time, and ensures a maintained and full battery charge. The IOTA 
IQ-TURBO monitors the battery at all times. If the DLS voltage remains in the Float stage for seven 
days, the IOTA IQ-TURBO will automatically initiate the Maintenance Cycle for a predetermined 
time to help maintain the battery, and then resume float stage charging. 

ATTENTION: While the 

IQ-TURBO is designed to accommodate most flooded lead acid batteries, always refer 
to the manufacturer’s specifications for your battery’s allowable charging parameters

.

INSTALLATION

The LED Indicator on the IQ informs the user of the DLS charging state and the battery charge 
status. When first activated, the IQ will read the number of cells in the battery and indicate the 
voltage of the battery through a number of flashes. 

Refer to Figure C.

LIT/FLASHING LED

 - After detecting the battery, the IQ-TURBO will initiate a Bulk Charge phase. 

When the IQ-TURBO is in the Bulk Charge mode, the green LED indicator will flash rapidly (ap-
prox. 2 flashes per second). When the Bulk Charge is complete, the IQ-TURBO will begin the 
Float Charge phase and the LED will remain lit (no flashing). Refer to 

Figure B

 for Charge Stage 

descriptions.

Figure B: Charge Stage Descriptions

OPERATION AND LED INDICATOR REFERENCE

P.O. BOX 11846  TUCSON, AZ 85734 

(520) 294-3292   •  FAX (520) 741-2837

www.iotaengineering.com

Figure C: LED Code Table

DUAL VOLTAGE JACK

IQ CHARGE CONTROLLER

FIGURE A. IQ INSTALLATION

*Location of the Dual Voltage Jack may vary depending on 
the DLS Model.

TURBO

12-VOLT / 24-VOLT

13.6 / 27.2 

14.78 / 29.56 

14.51 / 29.02 

BULK

ABSORPTION

FLOAT

MAINTENANCE

The Bulk State charges the battery at the 
full-rated output of the charger, reducing 
the time it takes to charge the battery.

The Absorption State delivers a constant 
charge for a set period of time to ensure that 
the battery receives a full and complete charge.

Once the battery has been fully charged, the 
Float State maintains a full charge to the battery 
while minimizing “gassing.”

If the battery has remained in the Float State for
seven days, the IQ automatically provides an
equalization charge to dissolve any sulfate layer
on the battery’s plates and to avoid stratification.