background image

 

                                    SF6 P2 Instrument User Manual V1.2 

 

Unrivalled Gas Detect

ion.

                

Page 11 of 16

                                                      

ionscience.com

 

 

 

 

O2 sensor 

 

 

 

 

 

 

 

 

 

 

 

 

 

Functionality 

The optionally available O2 sensor continuously measures the O2 content in the ambient air, and reports it to the 
network controller if present. 
 
An alarm condition on both the measuring station and network controller is raised whenever the oxygen level is 

outside the allowed range of 16…25%.

 

 

Physical location 

The O2 sensor is part of the SmartSensor, it is found protruding downwards from it. 
 

Sensor Type 

The O2 sensor is of galvanic cell type. It exhibits low cross sensitivity to CO2 and other gases, good stability and 
linearity over its range. 
 

Sensor Lifetime 

With a reasonable safety margin, sensor life is fixed at one year, no matter if shelfed or used 

 this is due to the nature 

of galvanic cells, in which the chemical reaction goes on at all times as long as oxygen is present. 
When lifetime is over, the SmartSensor must be replaced against a fresh, readily calibrated one. 
 

User Interface 

When a low oxygen condition is encountered, the measuring station will issue an alarm, involving the built in alarm 
buzzer, the red alarm lamp, and the alarm relay. The low oxygen condition will be reflected by the yellow "500" and 
"1000" ppm lamps flashing. 
In case of a high oxygen condition, the same applies, except that the "1500" and "2000" ppm lamps 
will flash. 
On the SF6 NETWORK CONTROLLER P2NC, the O2 status will be marked as "OK", "HI", or "LO", 
respectively, for each measuring station. 
 

Safety 

Should the O2 sensor fail, be missing or spent, a low oxygen alarm will be issued. 
 
 
 
 
 

 

 

 

 

Summary of Contents for SF6 AREACHECK P2

Page 1: ...Unrivalled Gas Detection ionscience com Register your instrument online to receive your extended Warranty SF6 P2 Instrument User Manual V1 2...

Page 2: ...y Thank you for purchasing your Ion Science instrument The standard warranty of your instrument can be extended to up to two years To receive your extended warranty you must register your instrument o...

Page 3: ...inie 73 23 EWG erg nzt durch 93 68 EWG Low Voltage Equipment Directive 73 23 EEC amended by 93 68 EEC Directive des equipements basse tension 73 23 CEE amend e par 93 68 CEE Angewendete harmonisierte...

Page 4: ...rtup 7 Measuring interval 7 Indicator lights 7 Lamp test and manual reset 8 Configuration via the PC interface 9 Connecting to the host computer 9 User parameters 9 Changing the sensor unit 10 O2 sens...

Page 5: ...6 ionscience com Installation Location SF6 AREACHECK P2 is designed for indoor wall mounting Since SF6 tends to sink towards the ground in undisturbed air we suggest to place it approx 50 60 cm above...

Page 6: ...plies in case of power failure and whenever the instrument is taken into setup mode via the host computer interface via the RS232 connector The leftmost 6 position clamp block is provided for network...

Page 7: ...SF6 P2 Instrument User Manual V1 2 Unrivalled Gas Detection Page 6 of 16 ionscience com Network diagram...

Page 8: ...tomatically return to full sensitivity Since a reset is also performed when the instrument is taken into setup mode via the host computer interface the above also applies in this case After Power up o...

Page 9: ...s reflect the last sampling period s result in terms of alarm levels as designated On instruments equipped with the optional oxygen sensor these lights have the following additional functions The two...

Page 10: ...ard configuration also known as 9600 8 N 1 Further select none for the handshake protocol and TTY as emulation if available The option append CR for received lines should be checked for a more readabl...

Page 11: ...ensor Fit the replacement SmartSensor Power up the P2 insert fuse observing the hints below NOTE To precisely determine SF6 concentration SF6 AREACHECK P2 requires a reference value representing clean...

Page 12: ...easonable safety margin sensor life is fixed at one year no matter if shelfed or used this is due to the nature of galvanic cells in which the chemical reaction goes on at all times as long as oxygen...

Page 13: ...500 ppm O2 1 Mains power 100 240VAC 50 60Hz Power consumption 18 VA Operating temperature range 5 C 45 C Storage temperature range 20 C 60 C Operating humidity range 10 90 non condensing Max load rel...

Page 14: ...that your Extended Warranty Period has been activated and processed Full details along with a copy of our Warranty Statement can be found by visiting www ionscience com Service Ion Science is pleased...

Page 15: ...w ism d de Email info ism d de Italian Office ION Science Italia Via Emilia 51 c 40011 Anzola Emilia Bologna ITALY Tel 39 051 0561850 Fax 39 051 0561851 Web www ionscience com it Email info ionscience...

Page 16: ...V1 1 Layout and font update 28 01 13 SF6 P2 V1 1R Logo only 01 08 2017 SF6 P2 V1 2 Design update 05 05 2020 Disclaimer Information in this manual document is subject to change without notice and does...

Reviews: