Ion Technologies SHR-HR

Submersible Sewage Pump

Single Seal, Single Phase, & Three Phase Power

OPERATION MANUAL

Dated: 11/27/2017

Document Name: SHR-HR_OM.indd

Page 3 of 8

www.ionproducts.net

directly across the line.

To Connect Pump

Run wire from pump to the control box or appropriate 

junction box suitable for enclosing splice connections.  

With  power  off,  connect  green  (ground)  line  to 

ground lug. Connect black (power) wires to power 

lead terminals. Make sure that all wires are not in a 

position to be pinched or shorted when installed. See 

wiring diagrams, page 5.

All three phase motors can run in either direction. 

Rotation can be changed by interchanging any two 

line leads at magnetic starter.

CAUTION:

  Be  sure  circuit  breaker  is  off 

before making this change.

To find if rotation is correct operate pumps and check 

delivery operation. If flow and head is slow (refer to 

pump curve shown in this manual) the rotation is 

wrong. With duplex pumps check operation of both 

pumps.

All pump impellers either single or three phase must 

turn counterclockwise when looking into pump inlet.  

If uncertain of rotation, turn off power and lift pump 

from basin with cord connected and lay pump on side 

so impeller can be seen. Turn on power and start 

pump using hand position of H-O-A switch. Turn on 

and off fast, so that coast of impeller can be seen.

WARNING: 

Never put hand or fingers on the 

impeller. Interchange any two line leads at the 

magnetic starter to change rotation.

Pump does not run or start when water is up in 

tank.

1.  Check for blown fuse or tripped circuit breaker.

2.  Check for burned-out motor. Occasionally 

lightning can damage a motor even with 

lightning protection.

3.  Where plug-in cords are used be sure contact 

blades are clean and making good contact. Do 

not use plug-in cords inside a basin or wet well.

Pump runs but does not deliver flow

1.  Check for air lock. Start and stop pump several 

Troubleshooting

times. If this does not help it may be necessary 

to loosen a union in the discharge line to relieve 

air lock.

2.  Check valve may be installed backward. Check 

flow arrow on valve bod. Check shut-off valve. 

It may be closed.

3.  Check vertical elevation. It may be higher than 

pump can develop. (See pump curve page 4.)

4.  Pump inlet may be plugged. Remove pump to 

check.

CAUTION:

 Follow proper lockout procedure 

before working on pump. If control panel is 

remote from pump, disconnect lead wires to motor so 

that no one can turn the circuit breaker back on.

Motor Data

Model

HP

Volts Phase Hertz

MSP-SHR50-11

½

115

1

60

MSP-SHR50-21

½

230

1

60

MSP-SHR50-23

½

230

3

60

MSP-SHR100-21

1

230

1

60

MSP-SHR100-23

1

230

3

60

MSP-SHR150-21

½

230

1

60

MSP-SHR150-23

½

230

3

60

MSP-SHR200-21

2

230

1

60

MSP-SHR200-23

2

230

3

60

MSP-HR50-11

½

115

1

60

MSP-HR50-21

½

230

1

60

MSP-HR50-03

½

208

3

60

MSP-HR50-23

½

230

3

60

MSP-HR50-43

½

460

3

60

Summary of Contents for SHR series

Page 1: ...n connected to system WARNING Risk of Asphyxiation Installer s and or service personnel must use proper personal protective equipment and follow OSHA 29 CFR 1910 146 or OSHA 29 CFR 1926 Pump may be installed in a location classified by as a confined space WARNING Risk of fire or explosion Do not smoke or use open flames in or around this system This system is not intended for use in hazardous loca...

Page 2: ...ompartment of septic tanks for pumping to pressure sewer mains gravity Recessed Impellers Air Locking Motor Types Installation sewers leach fields or evaporation mounds WARNING Basin must be vented in accordance with local plumbing codes These pumps are not designed for and CANNOT be installed in locations classified as hazardous in accordance with the National Electric Code ANSI NFPA 70 Pumps are...

Page 3: ...ast of impeller can be seen WARNING Never put hand or fingers on the impeller Interchange any two line leads at the magnetic starter to change rotation Pump does not run or start when water is up in tank 1 Check for blown fuse or tripped circuit breaker 2 Check for burned out motor Occasionally lightning can damage a motor even with lightning protection 3 Where plug in cords are used be sure conta...

Page 4: ...logies SHR HR Submersible Sewage Pump Single Seal Single Phase Three Phase Power OPERATION MANUAL Dated 11 27 2017 Document Name SHR HR_OM indd Page 4 of 8 www ionproducts net MSP SHR Dimensions MSP HR Dimensions ...

Page 5: ...ogies SHR HR Submersible Sewage Pump Single Seal Single Phase Three Phase Power OPERATION MANUAL Dated 11 27 2017 Document Name SHR HR_OM indd Page 5 of 8 www ionproducts net MSP HR Performance MSP SHR Performance ...

Page 6: ... Three Phase Power OPERATION MANUAL Dated 11 27 2017 Document Name SHR HR_OM indd Page 6 of 8 www ionproducts net Wiring Diagrams Voltage Black White Red Together 230 1 7 2 8 3 9 4 5 6 Leads 3 Phase Dual Voltage Winding 230 V 3 Phase 230 V 3 Phase 1 2 HP 230 V 1 Phase P S C ...

Page 7: ...Ion Technologies SHR HR Submersible Sewage Pump Single Seal Single Phase Three Phase Power OPERATION MANUAL Dated 11 27 2017 Document Name SHR HR_OM indd Page 7 of 8 www ionproducts net Notes ...

Page 8: ...o actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above 3...

Reviews: