16
MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA
9. Push the ferrule all the way in and then screw
it in.
NOTICE
: if it is necessary to unscrew the
ferrule, to prevent damaging the closure
mechanism, press and then turn the ferrule in
a counter-clockwise direction.
10. Fasten the sensor case to the plate.
3.2.2 Procedure with cable already
with terminal
Note
: this procedure is possible only if the cable already
has a terminal with a non-industrial RJ45 connector.
1. Expand the cable protector using your hands,
pulling it right and left to enlarge the hole.
2. Insert the cable in the cable protector by
pressing firmly.
3.2.3 Assemble the sensor with
the MSK-101-BM bracket (sensor
directed to the right)
1. Using the prepared holes, direct the sensor
plate as shown in the figure and fasten it to
the wall or to the junction box with two screws
(not provided). See "Back plate dimensions"
on page 31.
2. Fasten the bracket to the plate, passing the
Ethernet cable into the bracket.
3. Insert the ferrule, the cable protection ring
and the cable protector in the cable and insert
the RJ45 connector into the Ethernet port, see
steps 2–9 of the "Assemble the sensor" on
the previous page procedure.
3. Installation and use