8.3.9 Multi-control unit Synchronization
Example with two ISC-B01 control units.
Nota
: only if the Inxpect Safety application supports the function.
Digital I/O settings (through the Inxpect Safetyapplication)
Control unit #1
l
Control unit channel 0
l
Digital input #1 Acquisition Trigger
Control unit #2
l
Control unit channel 1
l
Digital input #1 Acquisition Trigger
8.4 Parameters
8.4.1 Parameter list
Parameter
Min
Max
Default value
Settings > Account
Password
-
-
Not available
Settings > General
Operational frequency
Full BW, Restricted BW
Full BW
Configuration
Number of installed sensors
1
6
1
Plane
Dim. X: 1000 mm
Dim. Y: 1000 mm
Dim. X: 20000 mm
Dim. Y: 65000 mm
Dim. X: 8000 mm
Dim. Y: 4000 mm
Position (for each sensor)
X: 0 mm
Y: 0 mm
X: 65000 mm
Y: 65000 mm
X: 1000 mm
Y: 1000 mm
Rotation (for each sensor)
0°
359°
0°
Inclination (for each sensor)
-90°
90°
0°
Sensor installation height (for each sensor) 0 mm
10000 mm
0 mm
Detection Distance 1(for each sensor)
0 mm
4000 mm
1000 mm
Detection Distance 2 (for each sensor)
0 mm
3000 mm
0 mm
8. Technical references
LBK System Series | Instruction manual v1.2 SET 2021| SAF-UM-LBKBus-en-v1.2 | © 2020-2021 Inxpect SpA