Goodrive600 series high-performance multifunction VFD
Basic operation guidelines
-103-
Function code
Name
Description
Default
P10.16
Multi-step speed 7
-100.0
–100.0%
0.0%
P10.17
Running time of step 7 0.0
–6553.5s (min)
0.0s
P10.18
Multi-step speed 8
-100.0
–100.0%
0.0%
P10.19
Running time of step 8 0.0
–6553.5s (min)
0.0s
P10.20
Multi-step speed 9
-100.0
–100.0%
0.0%
P10.21
Running time of step 9 0.0
–6553.5s (min)
0.0s
P10.22
Multi-step speed 10
-100.0
–100.0%
0.0%
P10.23
Running time of step 10 0.0
–6553.5s (min)
0.0s
P10.24
Multi-step speed 11
-100.0
–100.0%
0.0%
P10.25
Running time of step 11 0.0
–6553.5s (min)
0.0s
P10.26
Multi-step speed 12
-100.0
–100.0%
0.0%
P10.27
Running time of step 12 0.0
–6553.5s (min)
0.0s
P10.28
Multi-step speed 13
-100.0
–100.0%
0.0%
P10.29
Running time of step 13 0.0
–6553.5s (min)
0.0s
P10.30
Multi-step speed 14
-100.0
–100.0%
0.0%
P10.31
Running time of step 14 0.0
–6553.5s (min)
0.0s
P10.32
Multi-step speed 15
-100.0
–100.0%
0.0%
P10.33
Running time of step 15 0.0
–6553.5s (min)
0.0s
P10.34
ACC/DEC time of steps
0
–7 of simple PLC
0x0000
–0XFFFF
0000
P10.35
ACC/DEC time of steps
8
–15 of simple PLC
0x0000
–0XFFFF
0000
P17.27
Present step of simple
PLC
Used to display the present step of the simple
PLC function.
0
5.6.16 PID control
PID control, a common mode for process control, is mainly used to adjust the inverter unit output frequency or output
voltage through performing scale-division, integral and differential operations on the difference between feedback signal
of controlled variables and signal of the target, thus forming a negative feedback system to keep the controlled variables
above the target. It is suitable for flow control, pressure control, temperature control, and so on. The following is the basic
schematic block diagram for output frequency regulation.
+
-
Reference-
Feedback<P09.08?
P09.10
(PID output lower limit)
P09.09
(PID output upper limit)
0
1
P09.03
(PID output characteristics)
PID output
P17.00
P17.23
P09.08 (Limit of PID control
deviation)
P09.02
(PID feedback source)
P09.00
(PID reference source)
P17.24
PID feedback
value
PID reference
value
Set frequency
0
1
2
3
4
5
6
7
8
9
10
11
12
Keypad
AI1
PROFIBUS/DeviceNet
CANopen
Modbus
Multi-step speed
AI3
AI2
Ethernet
EtherCAT/PROFINET
AI1
PROFIBUS/DeviceNet
CANopen
Modbus
AI3
AI2
Ethernet
Y
N
PID stops
adjustment
Pre-set PID reference
of keypad
Keep present frequency
Terminal function 25
(Pause PID control)
Valid
Invalid
Kp P09.04(proportional gain)
Ti P09.05 (integral time)
Td P09.06 (differential time)
P09.01
PLC card
EtherCAT/PROFINET
PLC card
Reserved
Reserved
0
1
2
3
4
5
6
7
8
9
10
Reserved
Reserved