background image

1.24.14 05638B © Inovonics, 2014 - www.inovonics.com P/N 7102855 Rev. B

EN1240-60 EchoStream® Activity Sensor

Installation Instructions

1 Overview

The EN1240-60 activity sensor is designed specifically for residential and 
senior living environments where a notification of a daily activity is 
necessary. The EN1240-60 leverages the latest motion detector 
technology, including white light and pet immunity, to ensure performance 
accuracy. Selectable fixed sleep intervals of two, four, or six hours are used 
to minimize wireless traffic in large installations, while confirming daily 
resident activity. Check-in messages are sent every 60 minutes to provide 
effective notification of recent resident activity even when the device is in 
the fixed sleep cycle.

Note: 

For UL 2560 installations, refer to the 

EN6080 Area Control Gateway 

Installation Instructions

.

Note: 

In UL 2560 installations, transmitters send a check-in message every 

60 minutes.

Caution: 

The EN1240-60 needs one minute for stabilization after power 

up. During the stabilization period, the LED will blink twice per second, and 
the EN1240-60 will not be operational.

Caution: 

Prior to operation, the EN1240-60 must be acclimated to the 

temperature of the install environment for a period of 60 minutes.

Caution: 

The EN1240-60 activity sensor is not designed for use as a 

security system motion detector.

1.1 Maximum Number of Repeaters for a UL 2560 
Installation

To achieve the 99.99% alarm message reliability required for UL 2560 
compliance, system installations must operate within the following limits for 
end device and repeater counts.

1.2 Inovonics Wireless Contact Information

If you have any problems with this procedure, contact Inovonics Wireless 
technical services:

• E-mail: [email protected]
• Phone: (800) 782-2709; (303) 939-9336

1.3 EN1240-60 Internal Components

 Figure 1  

EN1240-60 components

1.4 What’s In The Carton

• Three wall mount screws
• Three wall mount anchors
• One selection jumper
• One 3.0V lithium battery

2 Installation and Startup

2.1 Installation Notes

• These products are designed to be installed and maintained by 

professional security technicians.

• Products are intended for indoor use.
• Manually test all products weekly.

End Devices

Maximum 
Repeaters

150

397

250

386

350

375

500

360

1000

313

2000

238

3000

184

A

Frequency band 
selection pins

B

Reset button

C

Pulse count selection 
pins

D

Pet immunity selection 
pins

E

Test mode reed 
switch

F

Sleep duration 
selection pins

G

Sensitivity adjustment 
dial

H

Battery

I

Case tamper switch

J

Sleep duration selection 
pins

K

Sleep time 
selection pins

C

A

D

B

E

G

F

H

I

K

J