15
2.2 Menu structure:
V1.8
System
Firmenware
V 1.8
Factory Reset
Yes/No (Reset to factory settings)
Signal Lost
Hold On / Black
Break Time
1- 4
DisplayBlackLight Yes/No (With the setting <Yes> the lighting is always on.
With <No> it goes out after 30s.)
Setup
Network Setting
IP Mode
Manual / DHCP
IP Adress
xxx.xxx.xxx.xxx
Subnet Mask
255.xxx.xxx.xxx
DMX Out
DMX Out 1
DMX A / DMX B / ArtNet
DMX Out 2
DMX A / DMX B / ArtNet
DMX Out 3
DMX A / DMX B / ArtNet
DMX Out 4
DMX A / DMX B / ArtNet
DMX Out 5
DMX A / DMX B / ArtNet
DMX Out 6
DMX A / DMX B / ArtNet
DMX Out 7
DMX A / DMX B / ArtNet
DMX Out 8
DMX A / DMX B / ArtNet
Control buttons:
You have direct access to all functions to be configured via the control buttons.
Button
Function
MENU
To jump back to the previous level and to the start display.
▲
Calls up the next menu item and increases the values during the setting process.
▼
Calls up the previous menu item and reduces the values during the setting process.
ENTER
Calls up the menu and the next menu item and activates the setting process of a value.
To operate as an Art-Net distributor, the DMX universes must be assigned to the DMX outputs and the network
settings must be configured. If the device is used as a pure DMX splitter, only the DMX inputs have to be assigned
to the DMX outputs and the network settings can be omitted. It would be possible to operate the device
simultaneously as an Art-Net distributor and DMX splitter. In this case, both
the DMX assignments and the network settings are made. The DMX inputs and universes
can be freely assigned to the DMX outputs.
2.3 Configuration:
Enter the IP address:
Press the <ENTER> key to make the selection.
Use the <▲> and <▼> keys to select the <SETUP> setting and confirm with <ENTER>
Use the <▲> and / ▼> keys to select the <NETWORK SETTING> setting and confirm with <ENTER>. There you
have the option of setting the <IP MODE> between <Manual> or <DHCP>.
If the <IP MODE> is set as <Manual>, you can set the <IP ADDRESS> and <SUBNET MASK>.
Enter the <Subnet mask>:
The subnet mask must be left at 255.0.0.0 in accordance with the Art-Net specifications.
Configuration of the connections in the menu <DMX-Out 1 to 8>
Signal assignment for DMX outputs 1 to 8:
Select the setting <
DMX A
> or <
DMX B
> for signal input via one of the DMX inputs or <
ArtNet
> for Art-Net
operation.
To select <
Art-Net
>, the parameters <
Net
>, <
SubNet
> and <
Univ
> must be set in the submenu in accordance
with the Art-Net specifications.