Optidrive E3 Advanced Technical Manual Issue 05.Docx
6 / 69
2
. Opt
id
rive
E3
Par
amet
er
Set Ov
er
vi
ew
2
Optidrive E3 Parameter Set Overview
2.1
About this section
This document provides a list of the available parameters, and a description of their respective functions, for the Optidrive E3.
2.2
Parameter Structure Overview and Access
The parameter set is arranged in Groups according to the following structure:-
Parameter Group
Range
Access Level
Access Type
P00
P00-01 to P00-20
Extended
Read Only
P00-21 to P00-50
Advanced
Read Only
Basic Parameters
P-01 to P-14
Basic
Read / Write
Extended Parameters
P-15 to P-50
Extended
Read / Write
Advanced Parameters
P-51 to P-60
Advanced
Read / Write
Access to all parameter groups is controlled by setting P-14 as follows
P-14 = P-37 (Factory setting: 101) Allows Extended Parameter Access
P-14 = P-37 + 100 (Factory Setting: 201) Allows Advanced Parameter Access
In order to prevent possible damage to the drive and connected machinery, certain parameters are locked during operation of the drive to
prevent change. In the case that the drive is enabled, and the user tries to change the parameter, an “L” is shown on the left of the display.