Invertek Drives 82-OPT-2-ENCOD-IN User Manual Download Page 1

LED Status Indication

LED A

(Green)

LED B

(Red)

The encoder module has 2 LEDs – LED A (Green) and LED B (Red).

  

LED A indicates power

  

LED B indicates a wiring fault condition.

The fault code is indicated on the drive display. Please see 

Error Code 

Defi nitions

. For transient faults, the LED will remain illuminated for 50ms to 

notify a fault on the module.

Mechanical Installation

  

Option Module inserted into 
Optidrive Option Module Port 
(please see diagram opposite).

  

DO NOT use undue force in inserting 
the option module into the options port.

  

Ensure the option module is fi tted 
securely before powering on the 
Optidrive.

  

Remove terminal block header from 
option module prior to tightening 
connections. Replace when wiring is 
completed. Tighten to Torque setting 
provided in Specifi cations.

1 2 3 4 5 6

Compliance

Hereby, Invertek Drives Ltd declares that the Optidrive Encoder Interface. 
Model Code: OPT-2-ENCOD-IN and OPT-2-ENCHT is in compliance 
with Directive 2014/30/EU, 2014/35/EU, 2011/65/EU
The EU declaration of conformity is available on request from your Invertek 
Drives Sales Partner.

User Guide

OPTIDRIVE Encoder Interface

Optidrive Encoder Interface Module User Guide

   |   Version 2.00

www.invertekdrives.com

Invertek Drives Ltd

Offa’s Dyke Business Park

Welshpool

Powys, UK

SY21 8JF

Ñ82-ENCOD-IN_V2.00PÓ

82-ENCOD-IN_V2.00

Compatibility

This Option is suitable for use on the following product ranges:

Optidrive P2 (ODP-2-.... Drives)
Optidrive Elevator (ODL-2-.... Drives)

Model Code

OPT-2-ENCOD-IN (5 Volt TTL Version)
OPT-2-ENCHT (8 – 30 Volt HTL Version)

Compatible Encoder Types

TTL Version : 5V TTL – A & B Channel with Compliment
HTL Version 24V HTL – A & B Channel with Compliment Note: +24V HTL 
encoder requires external supply voltage

Specifi cations

Power Supply Output: 

5V DC @ 200mA Max

Maximum Input Frequency: 

500kHz

Environmental: 

 

0◦C - +50◦C

Terminal Torque: 

 

0.5Nm (4.5 Ib-in)

Warranty

Complete Warranty Terms and Conditions are available upon request from 
your IDL Authorised Distributor.

Error Code Defi nitions

The following error codes are related to the encoder operation:

State

Indication

Indication



Communication loss

No communication between the encoder module and the drive.
Please check the module is properly fi tted into the slot.



Speed feedback error exceeds level set in P6-07

The estimated motor speed differs from the measured motor speed.
Check encoder connection, wire shielding, and values set in P6-07.



Encoder PPR motor speed mismatch

The encoder used must have a PPR value of at least 60. 

Motor nameplate RPM must be entered in P1-10.



Encoder Channel A Fault

Error normally caused by encoder wiring error.
Check encoder wiring and commissioning guidelines.



Encoder Channel B Fault



Encoder Channels A & B Faults

Reviews: