background image

User manual

Nano OUT

Soft >= v1.xx

INVEO s.c.

ul. Rzemieślnicza 21

43-340 Kozy

tel: +48 33 444 65 87

www.inveo.com.pl

[email protected]

Summary of Contents for Nano OUT

Page 1: ...User manual Nano OUT Soft v1 xx INVEO s c ul Rzemie lnicza 21 43 340 Kozy tel 48 33 444 65 87 www inveo com pl info inveo com pl...

Page 2: ...taking into account the basic principles of safety and maintenance Please also keep the user guide that you can use it during subsequent use Manufacturer Liability The manufacturer is not liable for a...

Page 3: ...GURATION 9 6 1 CHANGING THE PC SETTING FOR MODULE CONFIGURATION 9 6 2 CONFIGURATION OF THE MODULE MODULE THROUGH WEB BROWSER 10 6 3 CHANGING THE STATE OF THE OUTPUT 11 6 4 ACCESS CONFIGURATION 14 6 5...

Page 4: ...and important information Failure to follow warnings could cause injury or damage to the module Important information and guidelines Following this guidelines makes the use of the module easier Atten...

Page 5: ...th the contract of guarantee if the following conditions are met All repairs alterations extensions and device calibrations are performed by the manufacturer or authorized service supply network insta...

Page 6: ...ric pressure 700 1060hPa Environmental conditions for use Temperature 10 C to 30 C Relative humidity 30 to 75 Atmospheric pressure 700 to 1060hPa Recommended conditions for transportation Temperature...

Page 7: ...l SNMP protocol HTTP protocol User application communication protocol available for user NANO module is equipped with two LEDs indicators power and output status 5 2 Technical specification Power supp...

Page 8: ...minals RJ45 socket LAN network and POE Screw terminal input Teminal No Name Description 1 Relay output 2 RESET Reset to factory defaults IP 192 168 111 15 username admin password admin00 3 LAN LAN net...

Page 9: ...Start Control Panel Network connections Then right click on the current network connection and click Properties The configuration screen as shown below should be visible on the screen Choose the Inter...

Page 10: ...module Host Name NETBIOS host name of the module Enable DHCP When this box is ticked the module will get its address from DHCP server IP Address IP address of the module when configured manually Gatew...

Page 11: ...ut Visualisation of output state is shown below Output To change state of the output press Output On Off button Relay State shows current state of output relay Relay configuration can be change in Cha...

Page 12: ...ower reset Start On Enables relay after power reset Start Last Relay set to the same state as before power reset Dest Off Disables sending output state to different devices Dest 1 Sends state of outpu...

Page 13: ...User manual NANO OUT Page 13 of 24...

Page 14: ...dost pu Changing the password Enter old password into Current Password field Enter new password into New Password field and into Re type Password field then press Save Config to save new passwords En...

Page 15: ...e reboot 6 5 Managing the module using windows command line software The module can be operated using windows command line software the software is delivered with the module Syntax is as follows TCPRe...

Page 16: ...Parameters Parameter Description o 1 Output number for NANO always 1 h HOST Module IP address p PORT Module Port number s 0 1 Enables or disables output l Displays current state of output Examples En...

Page 17: ...egisters description is shown in tables below MODBUS TCP Coils Register Name Mode R read W write Description 1000 On1 R W Enable relay MODBUS TCP Holding Registers Registe r Name Mode R read W write D...

Page 18: ...tate enabled disabled In this case output inactive on 00000000 on Output state in 00000000 in In NANO OUT always read as 0 counter1 0 counter1 In NANO OUT always read as 0 temp1 0 0 temp1 In NANO OUT...

Page 19: ...User manual NANO OUT Page 19 of 24...

Page 20: ...24 31 CRC WWW control 15 99 x 1 status 0x55 off all other on x x x x x x CRC ON or NO Read channels 15 100 x x x x x x x x CRC CH7 CH0 Chx 2 bytes 1 output state 2 coil state Read channel name 15 101...

Page 21: ...CP 9761 Przyk adowe ramki Za czenie wyj cia 1 w trybie static SOF CMD CH D1 D2 D3 D4 D5 D6 D7 CRC 15 1 0 1 1 0 0 0 0 0 18 6 10 Communication with module from outside network If the module is in the LA...

Page 22: ...button 8 Restoring factory defaults In order to restore the module to its factory defaults press and hold reset button for at least 10 15 seconds The green LED will start flashing 4 times second With...

Page 23: ...for duration of programming To perform the programming operation go to the Windows command line Start Run type cmd and confirm with Enter Then navigate to the directory where the file resides and ent...

Page 24: ...Notes...