Log Card Action –
setting up event logging during a valid connection to the
master –
only for Card Action setting Reader card action
→
:
◦
As card action (if set)
– log events according to Card Action settings,
◦
Omit log action
– skip logging settings for Card Action.
•
Block RFID read
– block the reading of the next tag:
◦
Block
– when the RFID tag is read correctly, a value of 1 is written to Holding
Register 1. Only after the flag is reset will it be possible to read the next
transponder. (Set the Holding Register 1 register to the value 0).
◦
Continous
– automatically clear the read flag, which enables the immediate
reading of the next RFID tags.
•
Safe mode
– reader's reaction when modbus connection is broken:
◦
Disable
,
◦
No action
– no reader response to a tag proximity, for a broken connection,
◦
Standalone (Reader Card Action)
– switch to autonomous mode in case of
a broken connection.
•
Safe Timeout
– time without connection after which the reader will switch to
Safe mode
.
The device supports the following modbus functions:
•
0x01 Read Coils,
•
0x03 Read Holding Register,
•
0x05 Write Single Coil,
•
0x06 Write Single Register,
•
0x0F Write Multiple Coils,
•
0x10 Write Multiple Registers.
8.5.1 Addresses Holding Registers
Addr.# R/W Description
1
R/W Read flag
Read: 1 – a new transponder has been read
Write: 0 – reset the read flag
2
R
ID_LEN
3
R
UID/CSN [0]
4
R
UID/CSN [1]
5
R
UID/CSN [2]
6
R
UID/CSN [3]
7
R
UID/CSN [4]
8
R
UID/CSN [5]
9
R
UID/CSN [6]
10
R
UID/CSN [7]
11
R
UID/CSN [8]
12
R
UID/CSN [9]
13
R
Reserved
14
R
User ID – value FFFF/65535 means tag unknown
20
R/W Control output #1 according to settings from the I/O Settings tab
21
W
Control output #1 in bistable mode
22
W
Activation of output #1 for time specified as parameter (value * 0.1 sec)
23
W
Time blink_on (value * 0.1 sec)
User manual RFID IND2
Page
54
of
61