Owner’s Manual

 

Models 

 

Thank you for choosing  INVENTOR air 

conditioning system. For correct use of this unit, 

please read this manual carefully and keep it for 

future reference.

B2VI-09/B2VO-09
B2VI-12/B2VO-12

66129912898

Summary of Contents for B2VI-09

Page 1: ... Owner s Manual Models Thank you for choosing INVENTOR air conditioning system For correct use of this unit please read this manual carefully and keep it for future reference B2VI 09 B2VO 09 B2VI 12 B2VO 12 66129912898 ...

Page 2: ......

Page 3: ...lation service Notices for Installation Installation Drawing Installation of Indoor Unit Installation of Outdoor Unit Check after Installation and Operation Test This symbol stands for the items should be forbidden This symbol stands for the items should be followed Emergency operation The figures in this manual may be different with the material objects please refer to the material objects for re...

Page 4: ...e the accumulated dusts that may cause over heating or fire Never splice the power cord or use an extended cord It can cause overheating or fire When having a burning smell or smoke please turn off the power supply and contact with the service center If the abnormity still exists the unit may be damaged and may cause electric shock or fire Please read the following carefully before operating Notic...

Page 5: ... to them Don t insert your hands or stick into the air intake or outlet vents Don t use the air conditioner for other purposes such as drying clothes preserving foods etc To adjust the airflow direction appropriately When operating the unit to adjust the vertical and lateral air flow direction by use of remote controller Swing louver Guide louver Please don t cut off or damage the power cords and ...

Page 6: ...e there will be frost formed on the heat exchanger when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Principle Air conditioner absorbs heat from outdoor and transmits to indoor in this way to increase room temperature This is the heat pump heating principle its heating capacity will be reduced due to outdoor tem...

Page 7: ...4 Names and functions of each part Indoor unit Air in Air out Front panel Filter Guide louver Bind tape Connection wire Drainage pipe Remote control Outdoor unit Air in Air out Power cable Wall pipe ...

Page 8: ...ase temperature setting FAN Press it to set swing angle TIMER ON TIMER OFF CLOCK X FAN page 8 TEMP page 8 TURBO page 8 SLEEP page 8 Press it to turn on off the light LIGHT Press it to set fan speed Press it to set auto on timer Press it to set auto off timer Press it to set clock 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Operation of Remote Controller 5 NOTE X FAN is the alternative expression of BLOW for ...

Page 9: ...ration mode icon AUTO COOL DRY FAN or HEAT is only for heat pump models will show 15 is displayed when pressing the up down swing button Press this button again to clear the display 18 Up down swing icon After pressing TIMER button ON or OFF will blink This area will show the set time SET TIME display 21 Pressing TEMP button set temperature ambient temperature outdoor ambient temperature and blank...

Page 10: ... that goes from AUTO to then back to Auto Auto Low speed Medium speed High speed Press this button to set up down swing angle which circularly changes as below OFF 1 2 3 4 5 6 Operation of Remote Controller 7 After energization AUTO mode is defaulted In AUTO mode the set temperature will not be displayed on the LCD and the unit will automatically select the suitable operation mode in accordance wi...

Page 11: ...models SLEEP Press this button to go into the SLEEP operation mode Press it again to cancel this function This function is available in COOL HEAT Only for models with heating function or DRY mode to maintain the most comfortable temperature for you 10 12 13 8 Pressing CLOCK button blinks e h t s t s u j d a n o t t u b r o g n i s s e r p s d n o c e s 5 n i h t i W present time Holding down eithe...

Page 12: ...ote controller will not be used for a long time please Otherwise it may cause malfunction remove batteries to prevent batteries from leaking The operation should be performed in its receiving range It should be kept 1m away from the TV set or stereo sound sets If the remote controller does not operate normally please take the batteries out and reinsert them after 30 seconds If it still can t opera...

Page 13: ...select the COOL HEAT FAN mode automatically to obtain the comfortable effect At stopping When the unit is running press the ON OFF button of the manual switch the unit will stop work The code switch can be operated as follow At operation When the unit is stopped running adjust the code switch to AUTO the unit will enter into AUTO RUN mode The microcomputer will accord to the room temperature to se...

Page 14: ...ont panel Note Do not immerse the front panel into water so as to protect microprocessor components and circuit diagram on the front panel Care and Cleaning 11 Clean the air filter Take down the air filter Lift up the front panel Pull the air filter downwards to take it off as shown in Fig a b Use a vacuum cleaner to remove dust If the filters are dirty wash them with warm water and mild detergent...

Page 15: ...filters and Clear obstructions from the outdoor unit Check if the batteries of remote controller are replaced Check if the installation stand of the outdoor unit is damaged If damaged consult the technicians bodies of indoor and outdoor units Repaint the rubiginous place on the outdoor unit to prevent it from spreading Care and Cleaning ...

Page 16: ...s emitted in COOL mode During cooling operation a thin mist may be seen emitted from the indoor unit due to high room temperature and humidity After a period of time the mist will disappear with the decrease of room temperature and humidity 13 The air conditioner is not expected to be serviced by users Incorrect repair may cause electric shock or fire so please contact an authorized service center...

Page 17: ...heat sources in the room the the Check if there is magnetic or electrical interference near the unit that may affecting operation of the controller In this case pull the plug out and reinsert it Is the remote controller within its operating range or obstructed Check the condition of the batteries and replace them if necessary Check if the remote controller is damaged Water leakage of indoor unit W...

Page 18: ...s immediately stop all operations cut off the power supply and contact the authorized personnel Strong odours are emitted during operation The air switch or protection switch often trips Power cord and power plug is overheating n o i t a r e p o p o t S and cut off the power supply Troubleshooting Phenomenon Troubleshooting Indoor unit can not blow air Moisture on air outlet C5 Malfunction of conn...

Page 19: ...stallation Site Instructions 16 The unit should be installed only by authorized service center according to local or government regulations and in compliance with this manual Before installing please contact with local authorized maintenance center If the unit is not installed by the authorized service center the malfunction may not be solved due to incovenient contact between the user and the ser...

Page 20: ...witch with a contact separation of at least 3mm in all poles should be connected in fixed wiring The unit should be reliably earthed and connected to an exclusive earth device by the professionals 4 The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload Make sure the live wire neutral wire and earth wire in the family power socket are pr...

Page 21: ...r must have reliable earthing terminal Please do not connect the earthing wire with the following Water pipe Gas pipe Contamination pipe Other place that professional personnel consider is unreliable Notices for Installation 18 10A Air switch capacity Air conditioner W 09K 12K 5 Including an air switch with suitable capacity please note the following table Air switch should be included magnet buck...

Page 22: ...ace to the wall Air outlet side Space to the floor Above Above Above Above Above The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures 19 286 540 Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above e v o b A ...

Page 23: ...e hole to prevent the connection piping and wiring from being damaged when passing through the hole Install the water drainage pipe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor should wrap the insulation materials Wrenched Bent Flooded Indoor Outdoor Wall...

Page 24: ...f the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As show in Fig 8 Hange the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough As show in Fig 9 The height of the installed location should be 2 m or more ...

Page 25: ...ct wiring may cause malfunction of spare part After the wire has been fixed ensure there is free space between the connection and fixing places on the lead wire 5 1 0 10 pa 76cmHg 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open the handle of Lo manifold valv...

Page 26: ...e Is the voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the unit Is the electric wiring or piping connection installed correctly and securely It may cause electric malfunction or damage the parts Has the unit been securely earthed It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage...

Page 27: ...lthy filter and reinstall it after cleaning according to the installation instruction Do not use brush or hard objects to clean the filter After cleaning be sure to dry it in the shade The general service life for the healthy filter is about one year under normal condition As for silver ion filter it is ineffective when its surface becomes black green This supplementary instruction is provided for...

Page 28: ...additional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See Sheet 2...

Page 29: ...er of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m Ф6 Ф9 5 or Ф12 20 15 20 Ф6 or Ф9 5 Ф16 or Ф19 50 15 50 Ф12 Ф19 or Ф22 2 100 30 120 Ф16 Ф25 4 or Ф31 8 170 60 120 Ф19 250 250 250 Ф22 2 350 350 350 Configuration of connection pipe and additional volume of refrigerant ...

Page 30: ......

Page 31: ......