6
USER AND SAFETY INSTRUCTIONS
iV-Office ventilation device
•
Installation and operating instructions
1.2
Safety instructions
These installation and operating instructions are part of the ventilation unit and must be permanently
available. When handing the equipment / system to a third party, the installation and operating
instructions must be handed over also. Before performing any work on the equipment / system,
read the installation and operating instructions carefully and observe all information in this
section regarding installation, operation, cleaning and care. Also note the safety instructions
that precede the described handling instructions. Non-observance of safety warnings could
result in injury and/or property damage.
Intended use
The ventilation device is designed to ventilate dwellings and similar residential spaces.
It is controlled via an inVENTer system control unit.
General information
• Always observe the relevant standards, regulations and guidelines when installing the
equipment / system. In particular also applicable building regulations, fire safety regulations
and accident prevention regulations of the employers' liability insurance association.
• Use the equipment/system exclusively for the applications that are described in this
documentation and only in conjunction with components that are recommended, authorised
and described by inVENTer GmbH in this documentation. Changes or modifications
to the equipment/system are not permitted.
• Your ventilation unit is exclusively designed for use in ambient temperatures between
-20 and 50°C.
• Trouble-free and safe operation of the equipment / system depends on proper transportation,
proper storage and installation, as well as careful operation and cleaning / care.
Installation and assembly
• CAUTION:
The system may only be installed by qualified personnel.
• Before starting work, you should have a project plan showing the number of ventilation
devices, the location of the ventilation devices, the ventilation principle (cross ventilation,
single room ventilation, extract ventilation) and the associated controllers. The exact
positioning of the individual devices and control units must be checked at the installation site
and, if necessary, adapted to the local conditions with the involvement of the responsible
planner or user. For optimum functionality, it is recommended to install the unit at an
appropriate place in the upper wall area.
• WARNING:
For joint operation with open-flue and balanced-flue fireplaces, safety measures
must be taken to prevent a negative pressure from developing in the building. The
responsible chimney sweep and/or building planner decides which measures need to be
carried out.
• NOTE:
The ventilation device is not suitable for drying out buildings. Do not put it into
operation until the construction work has been completed.
• NOTE:
Contamination of components, e.g. by plaster residue, will damage the components!
Seal the ventilation device/air outlets of the ventilation device so they are dust-tight
throughout the construction work. Do not remove the thread locks until final assembly.
• NOTE:
Do not install the device near indoor air thermostats or in the immediate vicinity of/
above sensitive pictures or furniture.
• NOTE:
Observe the specified minimum clearances on both sides of the wall and frontally
to prevent unintentional mixing of different air flows and to ensure access to the device
and its components. A minimum distance of 1.2 m must be maintained between adjacent
air openings. (
, page 12 f.).