11
SYSTEM OVERVIEW: IV-LIGHT VENTILATION UNIT
11
iV-Light ventilation unit | Installation instructions
2.3 Control elements
The ventilation unit is operated via an inVENTer system controller.
Depending on the controller, different operating modes and functions can be set.
Designation
sMove
MZ-Home
inVENTer Connect
(Easy Connect e16)
Number of controll-
able ventilation units
Max. 8
Max. 16
(excl. sensors)
Max. 16
(incl. sensors)
Multi-zone control
No
Yes
(max. 4 zones with
max. 4 units [plus
sensors] per zone)
Yes
(max. 4 zones; any
number of units per zone)
Operating concept
•
Touch
•
Touch
•
Weekly timer
•
Touch
•
Ventilation profiles
•
App control
Operating modes
•
Heat recovery
•
Unidirectional
ventilation
•
Pause function
•
OFF
(standard only)
•
Heat recovery
•
Unidirectional
ventilation
•
Dehumidification
(integrated moisture /
temperature sensor)
•
Pause function
•
OFF
•
Heat recovery
•
Unidirectional
ventilation
•
Dehumidification and
other demand
ventilation
•
Pause function
(global and zonal)
•
Boost function
(global and zonal)
•
OFF
Fan speed
infinitely adjustable,
4 levels predefined
4 power levels,
freely selectable
4 power levels,
freely selectable
Unit
communication
Cable
Cable
868 MHz wireless
network cable
External interface
1 potential-free
switching contact per
controller:
•
Pressure switch (NC)
•
Other sensors (NO)
1 potential-free switch-
ing contact per
Clust-Air module
(max. 4)
•
Pressure switch
(NC/NO)
•
Other sensors (NO)
Several different
sensors per controller
platform
(zone division
and number of sensors
per zone arbitrary)
For detailed information, see the controller's installation and operating instructions.
Summary of Contents for 1001-0200
Page 1: ...www inventer de Installation instructions iV Light ...
Page 37: ...37 WARRANTY AND GUARANTEE 37 iV Light ventilation unit Installation instructions NOTES ...
Page 38: ...38 WARRANTY AND GUARANTEE 38 iV Light ventilation unit Installation instructions NOTES ...
Page 39: ...39 WARRANTY AND GUARANTEE 39 iV Light ventilation unit Installation instructions NOTES ...