31
Document Number
DCV-00214
Date Released
Mar. 2017
Revision Number/Security level
R00 S2
Retrofit G6+InvencoLink GVR Encore 500S (US) Installation Guide
2. Cable EK0124 has three connectors at one end and a single connector at the other end.
EK0124 is supplied with a “dummy plug” for safety in some installations. The plug looks like this:
Unplug and discard the female dummy plug from the three-connector end of EK0124.
a. For Side A, plug the now-exposed male orange connector into an available AC terminal
port on the AC voltage cable bus assembly in the dispenser, typically located somewhere
along the bottom of the electronics cavity.
b. For Side B, plug the now-exposed male orange connector into the available orange
female connector on the EK0124 from Side A.
Note
: There are several points of connection along the pre-existing AC voltage cable bus
assembly in the dispenser. Locate an unused terminal port. Do not unplug an occupied port.
MN0031 Nut placed
AC Voltage Bus (always black/white/green)
AC Terminals (may be orange in some dispensers)
EK0124
Dummy Plug