28
Document Number
DCV-00214
Date Released
Mar. 2017
Revision Number/Security level
R00 S2
Retrofit G6+InvencoLink GVR Encore 500S (US) Installation Guide
4.2
Pre-Installation Procedure
4.2.1 Communications
This Retro-Fit Kit does not include a communications method for the OPT. When this Retro-Fit Kit is being
installed on Side A (i.e. the first side) of the dispenser, a communications method MUST first be installed.
The approved communications methods are listed below.
UL Report Number
Kit Part Number
Retro-Fit Kit Description
MH61528
6009-0008-8801
InvencoLink DSP232
For Side B (i.e. the second side), you MUST have Side A (i.e. the first side) already installed, and you
may then proceed to §4.3 Installation Procedure.
For Side A (i.e. the first side), select the PSU Plate Assembly from this Retro-Fit Kit package and apply
the communications method selected from the table above, following the installation instructions supplied
with that Kit.
4.2.2 Gasket Installation
The MZ0108 RFK panel needs to have a gasket installed before it can be placed into the dispenser.
1. Place the MZ0108 panel face-up on a clean, soft surface.
2.
Locate the MP0653 gasket (it’s the pale grey one about 1/8” thick).
3. Peel the backing paper from MP0653 to expose the adhesive.
4. Line up the gasket along the bottom edge of MZ0108 as shown, taking care that the edge of the
gasket is touching the surface, before pressing the gasket onto MZ0108.
If you are gentle, you can reposition the gasket before pressing it down properly.
Apply gasket to
this surface first