23
Document Number
DCV-00214
Date Released
Mar. 2017
Revision Number/Security level
R00 S2
Retrofit G6+InvencoLink GVR Encore 500S (US) Installation Guide
30.
Unplug the printer’s power cable from the Power Supply Assembly terminal P4 for Side-A (P5 for
Side-B).
31.
Remove the Printer Cables from the Dispenser. Unfasten any cable restraints necessary and re-
fasten them after the printer cables are removed.
32. For a double-sided installation, repeat steps 1-31 for Side-B (if present).
Note
: The Encore 500-S communicates certain data amongst several dispenser components via
a LON cable assembly, commonly referred to as LON Headers. The LON cables need to be
connected to each necessary component in a “loop” or “Ring” setup, which is a network topology
that is set up in a circular fashion in such a way that they make a closed loop. In most cases the
necessary components that the LON loop is connected to are: the CPU Board, the CRIND
Control Node, and both Door Nodes. The CRIND Control Node is going to be removed from the
loop during this disassembly procedure, which will create an “opening” in the loop. This “opening”
needs to be closed in order for the components to communicate. Follow the steps 33-35 to
correctly remove the components and close the opening in the loop.
33.
Identify the CRIND Control Node located on the upper electronics rail inside of the electronics
cavity, and the CPU Board mounted below. (Fig 1.17)
Printer USB Data
Cables
Printer Power
Cables