background image

Invacare® Perfecto₂™ V Oxygen Concentrator

Symbol

O

2

Purity

Indicator

Light

(LED)

Explanation

A

O

2

SYSTEM

OKAY

O

2

over

85%

GREEN

light

No action is
needed. Normal
for operation.

B

O

2

between
73% and

85%

YELLOW

light

(Solid)

Immediately call
supplier. You may
continue to use
the concentrator
unless instructed
otherwise by
your supplier.
Be certain that
backup oxygen is
nearby.

A
B

O

2

O

2

un-

known

GREEN

light with

YELLOW

light

flashing

Immediately
call supplier.
Oxygen sensor
is malfunctioning.
You may continue
to use the
concentrator.

Symbol

O

2

Purity

Indicator

Light

(LED)

Explanation

C

SYSTEM

FAILURE

O

2

below

73%

RED light

(Solid)

Continuous
Audible Alarm

Sieve-GARD™
Compressor
Shutdown

SYSTEM FAILURE.
Total unit
shutdown.
Immediately
switch to backup
oxygen supply
and call supplier.

D

Call Supplier

6.3.8 Elapsed Time Meter (Hour Meter)

The hour meter displays the cumulative number of hours
the unit has operated. Refer to

3.1 Component Identification,

page 14

for specific location.

28

1195056-B

Summary of Contents for Perfecto2 IRC5PO2VAW

Page 1: ...cto V Oxygen Concentrator IRC5PO2VAW en HomeFill System Compatible User Manual This manual MUST be given to the user of the product BEFORE using this product this manual MUST be read and saved for fut...

Page 2: ...m Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Making Life s Experiences Possible is a registere...

Page 3: ...ning the Nasal Cannula 23 6 3 3 Turning the Concentrator On 25 6 3 4 Flowrate 26 6 3 5 SensO2 Oxygen Purity Indicator 27 6 3 6 Initial Startup of the Concentrator 27 6 3 7 Explanation of Oxygen Purity...

Page 4: ...cates a potentially hazardous situation which if not avoided may result in property damage or minor injury or both Gives useful tips recommendations and information for efficient trouble free use Symb...

Page 5: ...ical Hazard Manufacturer Call supplier This product complies with Directive 93 42 EEC concerning medical devices The launch date of this product is stated in the CE declaration of conformity EC Repres...

Page 6: ...product if the patient is capable of spontaneous breath able to inhale and exhale without the use of a machine DO NOT use in parallel or series with other oxygen concentrators or oxygen therapy device...

Page 7: ...is not intended to sustain or support life The oxygen concentration level of the output gas ranges from 87 to 95 6 The oxygen is delivered to the patient through the use of a nasal cannula The Invaca...

Page 8: ...t the base B Specification Label is located on the back of the concentrator at the base C EU Representative label is located on the base D Phthalate label is located on the base E 2 2 General Guidelin...

Page 9: ...ire Textiles oil or petroleum substances grease greasy substances and other combustibles are easily ignited and burn with great intensity in oxygen enriched air and when in contact with oxygen under p...

Page 10: ...tricity created by any type of friction Keep the oxygen tubing cord and concentrator out from under such items as blankets bed coverings chair cushions clothing and away from heated or hot surfaces in...

Page 11: ...chemicals from airway contamination DO NOT use the concentrator in the presence of pollutants smoke fumes flammable anesthetics cleaning agents or chemical vapors WARNING Risk of Injury or Death To pr...

Page 12: ...adversely affect the flowrate and the percentage of oxygen and consequently the quality of therapy WARNING Risk of Injury or Damage Invacare oxygen concentrators are specifically designed to minimize...

Page 13: ...c interference in a typical home healthcare environment Use of this equipment in an environment with higher levels of interference could affect the accuracy of the oxygen concentration being delivered...

Page 14: ...xygen Concentrator 3 Components 3 1 Component Identification A Oxygen Outlet B Flowmeter C Elapsed Time Meter D Oxygen Purity Indicator Lights Fault and Power Indicator Lights E Circuit Breaker F Powe...

Page 15: ...HomeFill Home Oxygen Compressor The outlet fitting does not affect concentrator performance Refer to the HomeFill System user manual for connection and operating instructions When not in use the plug...

Page 16: ...Invacare Perfecto V Oxygen Concentrator 3 2 Pneumatic Diagram Fig 3 1 Concentrator without Humidifier Fig 3 2 Concentrator with Humidifier 16 1195056 B...

Page 17: ...ns to reduce the propagation of fire in the accessories for the safety of the patient and others If a commercially available fire activated flow stop device is used in the accessories setup it should...

Page 18: ...arton Unless the oxygen concentrator is to be used IMMEDIATELY leave concentrator in its packaging for storage until use is required 5 2 Inspection 1 Inspect examine exterior of the concentrator for n...

Page 19: ...injury during therapy The oxygen concentrator MUST be placed on a level surface for use DO NOT relocate the oxygen concentrator while in use WARNING Risk of Injury or Damage To avoid injury or damage...

Page 20: ...Connect Humidifier if so prescribed 6 3 1 Setting Up the Humidifier If Prescribed WARNING Risk of Injury or Damage To avoid burns from steam or hot water inhalation of water and or water damage to the...

Page 21: ...er Boil tap water for approximately 10 minutes and cool to room temperature prior to use CAUTION Risk of Damage Confirm the humidifier cap is not cross threaded on the humidifier bottle 3 Insert a fla...

Page 22: ...r K on the concentrator If using the optional accessory Humidifier Bottle Holder M1521 to position humidifier at patient side location place the accessory on a flat surface as close to the patient as...

Page 23: ...tubing Close supervision is necessary when the nasal cannula is used by impaired individuals or near children and or impaired individuals WARNING Risk of Injury or Death To reduce the risk of injury...

Page 24: ...pply tube B to the humidifier bottle outlet M For use without a humidifier bottle Attach the patient s nasal cannula supply tube B to the oxygen outlet connector K on the concentrator 4 After assembly...

Page 25: ...d look for bubbles indicating proper operation Wipe any excess water off the nasal prongs when finished before placing on the patient If there are no bubbles check all connections including humidifier...

Page 26: ...lly reassessed Use only the tubing and accessories that were used to determine the prescribed oxygen flow setting Do not set the flow above the RED ring An oxygen flow greater than 5 L min will decrea...

Page 27: ...dicator This feature monitors the purity of oxygen generated by the oxygen concentrator If purity falls below factory preset standards indicator lights on the control panel will illuminate 6 3 6 Initi...

Page 28: ...light with YELLOW light flashing Immediately call supplier Oxygen sensor is malfunctioning You may continue to use the concentrator Symbol O2 Purity Indicator Light LED Explanation C SYSTEM FAILURE O...

Page 29: ...of the concentrator To avoid damage or injury from electrical shock Turn Off the concentrator and unplug the power cord before cleaning DO NOT allow any cleaning agent to drip inside the air inlet and...

Page 30: ...f Damage To avoid damage to the internal components of the unit DO NOT operate the concentrator without the filter installed or with a dirty filter There is one cabinet filter located on the back of t...

Page 31: ...from infection or damage to concentrator Only qualified personnel should perform cleaning and disinfection of the oxygen concentrator and accessories between patients Follow these instructions to eli...

Page 32: ...CHEDULE OR BETWEEN PATIENTS Every 3 years of continuous use Equivalent to 26 280 hours Check Oxygen Concentration green indicator light Clean Replace Cabinet Filter s Refer to Cleaning the Cabinet Fil...

Page 33: ...orking towards ensuring that the company s impact on the environment locally and globally is reduced to a minimum We comply with the current environmental legislation e g WEEE and RoHS directives We o...

Page 34: ...blem recurs use a different outlet 3 Push reset circuit breaker If problem recurs call service supplier Alarm System Failure RED light illuminated Continuous Concentrator not operating power switch On...

Page 35: ...elow 0 5 L min use the Pediatric Flowmeter IRCPF16AW The use of the Pediatric Flowmeter will deactivate the Potential Obstruction Alert Alarm System Failure YELLOW light Illuminated Short beeps long p...

Page 36: ...7 to 95 6 at 0 5 to 5 L min 93 3 at 2 L min Concentration levels achieved after initial warm up period approximately 30 minutes Maximum Outlet Pressure 34 5 kPa 3 45 kPa 5 psi 0 5 psi Flow Range 0 5 t...

Page 37: ...essure Alarm w compressor shutdown Battery Free Power Loss Alarm SensO2 Oxygen System Possible Obstruction Alert Width 38 1 cm 1 cm 15 in 3 8 in Height 58 4 cm 1 cm 23 in 3 8 in Depth 30 5 cm 1 cm 12...

Page 38: ...Avoid deep pile carpets and heaters radiators or hot air registers Floor location only No confined spaces Example No closets Environment Smoke and soot free Tubing 2 1 m 7 ft cannula with a maximum 1...

Page 39: ...ons flicker emissions IEC 61000 3 3 Complies The Device is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply...

Page 40: ...nvironment If the user of the Device requires continued operation during power mains interruptions it is recommended that the Device be powered from an un interruptible power supply or a battery UT is...

Page 41: ...ts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a sho...

Page 42: ...RF communications equipment and the Device The Device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Device can...

Page 43: ...ency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer At 80 MHz and 800 MHz the separation distance for the higher...

Page 44: ...e Poirier SAS Route de St Roch F 37230 Fondettes Tel 33 0 2 47 62 64 66 Fax 33 0 2 47 42 12 24 contactfr invacare com www invacare fr Ireland Invacare Ireland Ltd Unit 5 Seatown Business Campus Seatow...

Page 45: ...z Suisse Svizzera Invacare AG Benkenstrasse 260 CH 4108 Witterswil Tel 41 0 61 487 70 80 Fax 41 0 61 487 70 81 switzerland invacare com www invacare ch United Kingdom Invacare Limited Pencoed Technolo...

Page 46: ...Notes...

Page 47: ...Notes...

Page 48: ...3 Tel 800 832 4707 www invacare com Manufacturer Invacare Corporation 2101 E Lake Mary Blvd Sanford FL 32773 United States Tel 407 321 5630 EU Representative Invacare Deutschland GmbH Kleiststra e 49...

Reviews: